OSHA SearchOSHA records by employer

HMBC Contractors LLC: OSHA inspections and violations

Portland, Oregon · Roofing Contractors · NAICS 238160

1inspections
3citation items
$2,600current penalties
Aug 24, 2023last inspection

OSHA inspectors have visited HMBC Contractors LLC in Oregon one time.

It opened on Aug 24, 2023 after a complaint, in Portland.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $2,600 in total, stand where OSHA first set them.

The rule cited most here is 1926.502 (fall protection systems), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. HMBC Contractors LLC averages $2,600 across 1 cited inspection.

HMBC Contractors LLC: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

391employers cited

33 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch HMBC Contractors LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346964687 OPENED AUG 24, 2023Closed

Complaint · Partial · Safety · 12 employees at the site · Closed Dec 28, 2023

17505 Ne San Rafael St, Portland, OR 97230 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.502(f)(1)(i) · Fall protection systems
Serious$2,600$2,600Sep 27, 2023Final
Citation 1, item 1b
29 CFR 1926.502(f)(2) · Fall protection systems
Serious$0$0Sep 27, 2023Final
Citation 1, item 1c
29 CFR 1926.502(f)(2)(i) · Fall protection systems
Serious$0$0Sep 27, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.502(f)(1)(i)

(i) When mechanical equipment is not being used, the warning line shall be erected not less than 6 feet (1.8 m) from the roof edge.

29 CFR 1926.502(f)(2)

(2) Warning lines shall consist of ropes, wires, or chains, and supporting stanchions erected as follows:

29 CFR 1926.502(f)(2)(i)

(i) The rope, wire, or chain shall be flagged at not more than 6-foot (1.8 m) intervals with high-visibility material;

Other roofing contractors employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.