OSHA SearchOSHA records by employer

Holiday Retirement dba Jordan Oaks: OSHA inspections and violations

Cary, North Carolina · Other Residential Care Facilities · NAICS 623990

2inspections
7citation items
$585current penalties
Jun 17, 2015last inspection

Since 2008, OSHA inspectors have visited Holiday Retirement dba Jordan Oaks in North Carolina 2 times.

The most recent inspection opened on Jun 17, 2015 as a planned inspection, in Cary.

In all, OSHA issued 7 citation items: 2 serious and 5 other-than-serious.

The proposed penalties came to $900; today they stand at $585, 35% less.

The rule cited most here is 1910.305 (electrical wiring methods), 2 times.

Among health care employers, the typical cited inspection since 2015 ends with a $1,050 penalty. Holiday Retirement dba Jordan Oaks averages $585 across 1 cited inspection.

Holiday Retirement dba Jordan Oaks: OSHA citation items per year, 2008 to 2015
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

228employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Holiday Retirement dba Jordan Oaks and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 317997708 OPENED JUN 17, 2015Closed

Planned · Complete · Health · 37 employees at the site · Closed Aug 31, 2015

10820 Penny Road, Cary, NC 27518 · Assisted Living Facilities for the Elderly · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$900$585Jul 15, 2015Closed
Citation 1, item 1b
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$0$0Jul 15, 2015Closed
Citation 2, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 15, 2015Closed
Citation 2, item 2
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$0$0Jul 15, 2015Closed

Inspection 312451115 OPENED SEP 29, 2008Closed

Planned · Complete · Safety · 35 employees at the site · Closed Dec 2, 2008

10820 Penny Road, Cary, NC 27511 · Other Residential Care Facilities · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 19, 2008Closed
Citation 1, item 2
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Nov 19, 2008Closed
Citation 1, item 3
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0Nov 19, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(5)(i)

(5) Transportation. (i) Chemical manufacturers, importers, or distributors shall ensure that each container of hazardous chemicals leaving the workplace is labeled, tagged, or marked in accordance with this section in a manner which does not conflict with the requirements of the Hazardous Materials Transportation Act (49 U.S.C. 5101 et seq.) and regulations issued under that Act by the Department of Transportation (49 CFR subtitle B).

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1910.213(c)(2)

(2) Each hand-fed circular ripsaw shall be furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator. The spreader shall be made of hard tempered steel, or its equivalent, and shall be thinner than the saw kerf. It shall be of sufficient width to provide adequate stiffness or rigidity to resist any reasonable side thrust or blow tending to bend or throw it out of position. The spreader shall be attached so that it will remain in true alignment with the saw even when either the saw or table is tilted. The provision of a spreader in connection with grooving, dadoing, or rabbeting is not required. On the completion of such operations, the spreader shall be immediately replaced.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other other residential care facilities employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.