OSHA SearchOSHA records by employer

Holts Stucco & Plastering, LLC.: OSHA inspections and violations

Fort Myers, Florida · Masonry Contractors · NAICS 238140

1inspections
8citation items
$6,480current penalties
Jun 10, 2015last inspection

OSHA inspectors have visited Holts Stucco & Plastering, LLC. in Florida one time.

It opened on Jun 10, 2015 as a planned inspection, in Fort Myers.

In all, OSHA issued 8 citation items: 8 serious.

The proposed penalties came to $10,800; today they stand at $6,480, 40% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 6 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Holts Stucco & Plastering, LLC. averages $6,480 across 1 cited inspection.

Holts Stucco & Plastering, LLC.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

318employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Holts Stucco & Plastering, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340693548 OPENED JUN 10, 2015Closed

Planned · Partial · Safety · 13 employees at the site · Closed May 16, 2016

14240 Mcgregor Blvd, Fort Myers, FL 33919 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,700$1,020Jul 21, 2015Final
Citation 1, item 2
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Serious$1,700$1,020Jul 21, 2015Final
Citation 1, item 3a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,700$1,020Jul 21, 2015Final
Citation 1, item 3b
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Serious$0$0Jul 21, 2015Final
Citation 1, item 3c
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$0$0Jul 21, 2015Final
Citation 1, item 4
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$2,000$1,200Jul 21, 2015Final
Citation 1, item 5
29 CFR 1926.452(n)(4) · Rules for each type of scaffold
Serious$1,700$1,020Jul 21, 2015Final
Citation 1, item 6
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$2,000$1,200Jul 21, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(4)

(4) Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm).

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other masonry contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.