OSHA SearchOSHA records by employer

Home Repair Inc: OSHA inspections and violations

Forest Lake, Minnesota · Roofing Contractors · NAICS 238160

3inspections
6citation items
$4,737current penalties
Oct 1, 2024last inspection

OSHA has inspected Home Repair Inc 3 times in Minnesota since 1993.

The latest one began on Oct 1, 2024 after a complaint, in Forest Lake.

Those inspections ended with 6 citation items: 6 serious.

Penalties were first proposed at $7,662 and now stand at $4,737, 38% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 2 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Home Repair Inc averages $2,275 (2 cited inspections).

Home Repair Inc: OSHA citation items per year, 1993 to 2024
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

375employers cited

35 of them in the same industry

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Home Repair Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347787285 OPENED OCT 1, 2024Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Jul 14, 2025

1954 Broadway Ave W, Forest Lake, MN 55025 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,100$1,050Oct 28, 2024Final
Citation 1, item 2
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$2,100$1,050Oct 28, 2024Final
Citation 1, item 3
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,650$825Oct 28, 2024Final

Inspection 317995090 OPENED JUN 29, 2015Closed

Planned · Partial · Safety · 3 employees at the site · Closed Aug 4, 2015

1954 Broadway Ave W, Forest Lake, MN 55025 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$250$250Jul 17, 2015Closed
Citation 1, item 2
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$1,375$1,375Jul 17, 2015Closed

Inspection 120417639 OPENED JUN 3, 1993Closed

Planned · Partial · Safety · 2 employees at the site · Closed Oct 12, 1995

680 N Snelling Ave, St Paul, MN 55104 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(4) · Scaffolds, general requirements
Serious$187$187Jul 12, 1993Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1820.6530

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(4)

(4) Each suspension rope, including connecting hardware, used on adjustable suspension scaffolds shall be capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to that rope with the scaffold operating at either the rated load of the hoist, or 2 (minimum) times the stall load of the hoist, whichever is greater.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(2)

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.