OSHA SearchOSHA records by employer

Home Solutions MD LLC: OSHA inspections and violations

Baltimore, Maryland · Residential Remodelers · NAICS 236118

1inspections
3citation items
$6,150current penalties
Mar 4, 2022last inspection

Home Solutions MD LLC has one OSHA inspection on record in Maryland.

OSHA opened it on Mar 4, 2022 after an accident, in Baltimore.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $6,150 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.850, preparatory operations (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Home Solutions MD LLC averages $6,150 over 1 cited inspection in that time.

Home Solutions MD LLC: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

189employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Home Solutions MD LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345818181 OPENED MAR 4, 2022Closed

Accident · Complete · Safety · 2 employees at the site · Closed Aug 26, 2022

42 S. Fulton Ave., Baltimore, MD 21223 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.850(a) · Preparatory operations
Serious$2,050$2,050Aug 10, 2022Final
Citation 1, item 2
29 CFR 1926.850(b) · Preparatory operations
Serious$2,050$2,050Aug 10, 2022Final
Citation 1, item 3
29 CFR 1926.854(b) · Removal of walls, masonry sections, and chimneys
Serious$2,050$2,050Aug 10, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.850 · Preparatory operations

29 CFR 1926.850(a)

(a) Prior to permitting employees to start demolition operations, an engineering survey shall be made, by a competent person, of the structure to determine the condition of the framing, floors, and walls, and possibility of unplanned collapse of any portion of the structure. Any adjacent structure where employees may be exposed shall also be similarly checked. The employer shall have in writing evidence that such a survey has been performed.

29 CFR 1926.850(b)

(b) When employees are required to work within a structure to be demolished which has been damaged by fire, flood, explosion, or other cause, the walls or floor shall be shored or braced.

29 CFR 1926.854 · Removal of walls, masonry sections, and chimneys

29 CFR 1926.854(b)

(b) No wall section, which is more than one story in height, shall be permitted to stand alone without lateral bracing, unless such wall was originally designed and constructed to stand without such lateral support, and is in a condition safe enough to be self-supporting. All walls shall be left in a stable condition at the end of each shift.