OSHA SearchOSHA records by employer

Honshy Electric Co. Inc.: OSHA inspections and violations

Miami, Florida · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

11inspections
15citation items
$6,508current penalties
Feb 12, 2020last inspection

Honshy Electric Co. Inc. has 11 OSHA inspections on record in Florida, the first in 1984.

OSHA's last visit started on Feb 12, 2020 as part of a related case, in Miami Beach.

Across those inspections OSHA issued 15 citation items: 11 serious and 4 other-than-serious.

OSHA proposed $7,640 in penalties. After settlements and reviews the total is $6,508, down 15%.

Most often, OSHA cited 1926.405, job-site wiring (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Honshy Electric Co. Inc. averages $0 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Honshy Electric Co. Inc.: OSHA citation items per year, 1984 to 2020
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

319employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Honshy Electric Co. Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344642939 OPENED FEB 12, 2020Closed

Unprogrammed related · Complete · Safety · 3 employees at the site · Closed Jul 29, 2020

31 Venetian Way, Miami Beach, FL 33139 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(2) · Job-site wiring
Other-than-serious$0$0May 29, 2020Final

Inspection 313103749 OPENED JUL 21, 2009Closed

Planned · Partial · Safety · 10 employees at the site · Closed Oct 23, 2009

13110 Ne 8 Ave., Miami, FL 33186 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.51(a)(4) · Sanitation
Serious$525$394Jul 29, 2009Closed

Inspection 311082226 OPENED JUN 13, 2007Closed

Planned · Complete · Safety · 30 employees at the site · Closed Jul 30, 2007

350 S. Miami Avenue, Miami, FL 33130 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$1,100$825Jul 17, 2007Closed

Inspection 307297481 OPENED APR 15, 2004Closed

Unprogrammed other · Partial · Safety · 11 employees at the site · Closed Jun 3, 2004

1801 Se 17 Street, Ft Lauderdale, FL 33316 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(h) · Electrical equipment on job sites
Serious$625$469May 24, 2004Closed
Citation 2, item 1
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0May 24, 2004Closed

Inspection 305498982 OPENED AUG 26, 2002Closed

Unprogrammed other · Complete · Safety · 14 employees at the site · Closed Jan 2, 2003

101 Ocean Ave, Miami Beach, FL 33139 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$750$563Oct 22, 2002Closed
Citation 1, item 2
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$750$562Oct 22, 2002Closed

Inspection 301884714 OPENED MAY 11, 1999Closed

Unprogrammed other · Partial · Safety · 11 employees at the site · Closed May 11, 1999

13110 Ne 8 Ave., Miami, FL 33186 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,250$1,250Jun 4, 1999Closed

Inspection 109688002 OPENED JAN 19, 1994Closed

Unprogrammed related · Complete · Safety · 12 employees at the site · Closed Apr 25, 1994

101 Ocean Ave, Miami Beach, FL 33139 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.56(a) · Illumination
Serious$900$900Mar 7, 1994Closed
Citation 1, item 2
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$900$900Mar 7, 1994Closed

Inspection 101205201 OPENED APR 16, 1987Closed

Planned · Complete · Safety · 94 employees at the site · Closed Jun 1, 1987

13110 Ne 8 Ave., Miami, FL 33186 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$420$225May 6, 1987Closed
Citation 1, item 1b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0May 6, 1987Closed
3 older inspections

Inspection 17425463 OPENED JUN 18, 1985Closed

Unprogrammed related · Complete · Safety · 7 employees at the site · Closed Aug 7, 1985

8305 Sw 152nd Ave., Miami, FL 33193 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.400(a) · Introduction
Other-than-serious$0$0Jul 15, 1985Closed
Citation 1, item 2
29 CFR 1926.401(c) · [Reserved]
Other-than-serious$0$0Jul 15, 1985Closed

Inspection 1167469 OPENED JUN 19, 1984Closed

Accident · Partial · Safety · 3 employees at the site · Closed Jul 19, 1984

2103 Sw 22nd St (21/22 Center), Miami, FL 33145 · OSHA's record · Phone and website on Google Maps

Incident on Jun 16, 1984 (fatal): Electric shock - direct contact with exposed live parts

A CREW OF THREE ELECTRICIANS WAS PREPARING TO LEAVE THE FOURTH FLOOR WORK AREA W HERE THEY HAD BEEN INSTALLING ELECTRIC SERVICE FOR A RECENTLY PARTITIONED OFFICE . THEY HAD BEEN LOOKING FOR THE JUNCTION BOX (AT CEILING LEVEL) TO MAKE FINAL CO NNECTIONS FOR TWO EXIT SIGN LIGHTS. WHEN HE LOCATED THE BOX, THE SUPERVISOR DECI DED TO MAKE A LAST MINUTE CONNECTION. HE USED A WOODEN STEPLADDER TO REACH THE O VERHEAD SPRINKLER PIPE AND METAL DUCT WORK. HE HAD TO LAY ACROSS THE PIPE AND DU CTS IN ORDER TO CONNECT THE ENERGIZED 120-VOLT WIRING. HE RECEIVED A FATAL ELECT RIC SHOCK. THE IDENTIFIED CIRCUIT BREAKER, LOCATED IN THE PANELBOARD IN THE GROU ND FLOOR METER ROOM, COULD HAVE BEEN USED TO DEENERGIZE THE CIRCUIT.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.400(c)(1) · Introduction
Serious$420$420Jul 12, 1984Closed

Inspection 221861 OPENED MAR 14, 1984Closed

Unprogrammed related · Complete · Safety · 4 employees at the site · Closed Mar 23, 1984

8305 Sw 152nd Ave, Miami, FL 33193 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.400 · Introduction

29 CFR 1926.400(a)

(a) Installation safety requirements. Installation safety requirements are contained in §§ 1926.402 through 1926.408. Included in this category are electric equipment and installations used to provide electric power and light on jobsites.

29 CFR 1926.400(c)(1)

(c) Safety-related maintenance and environmental considerations. Safety-related maintenance and environmental considerations are contained in §§ 1926.431 and 1926.432.

29 CFR 1926.401 · [Reserved]

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(h)

(h) Identification of disconnecting means and circuits. Each disconnecting means required by this subpart for motors and appliances shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. These markings shall be of sufficient durability to withstand the environment involved.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.51 · Sanitation

29 CFR 1926.56 · Illumination

Other electrical contractors and other wiring installation contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.