OSHA SearchOSHA records by employer

Hop River Concrete Incorporated: OSHA inspections and violations

Glastonbury, Connecticut · Poured Concrete Foundation and Structure Contractors · NAICS 238110

5inspections
11citation items
$7,775current penalties
Jul 9, 2018last inspection

Hop River Concrete Incorporated has 5 OSHA inspections on record in Connecticut, the first in 2001.

OSHA's last visit started on Jul 9, 2018 as part of a related case, in Groton.

Across those inspections OSHA issued 11 citation items: 11 serious.

OSHA proposed $14,324 in penalties. After settlements and reviews the total is $7,775, down 46%.

Most often, OSHA cited 1926.501, fall protection in construction (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Hop River Concrete Incorporated averages $3,000 over 1 cited inspection in that time.

Hop River Concrete Incorporated: OSHA citation items per year, 2001 to 2018
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

87employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch Hop River Concrete Incorporated and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343467205 OPENED JUL 9, 2018Closed

Unprogrammed related · Partial · Safety · 24 employees at the site · Closed Dec 17, 2018

Groton Water Treatment Plant, Poquonnock Road, Groton, CT 06340 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.502(i)(2) · Fall protection systems
Serious$5,174$3,000Oct 9, 2018Final

Inspection 308273242 OPENED AUG 5, 2005Closed

Unprogrammed other · Partial · Safety · 30 employees at the site · Closed Sep 1, 2005

1 King Philip Drive, West Hartford, CT 06117 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$750Aug 22, 2005Closed
Citation 1, item 2
29 CFR 1926.501(b)(5) · Fall protection in construction
Serious$1,500$750Aug 22, 2005Closed

Inspection 116131137 OPENED JAN 12, 2004Closed

Unprogrammed other · Partial · Safety · 60 employees at the site · Closed Sep 13, 2004

189 Storrs Road, Mansfield Center, CT 06250 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.502(b)(1) · Fall protection systems
Serious$1,500$1,000Feb 2, 2004Closed
Citation 1, item 3a
29 CFR 1926.1052(b)(1) · Stairways in construction
Serious$2,100$1,000Feb 2, 2004Closed
Citation 1, item 3b
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$0$0Feb 2, 2004Closed
Citation 1, item 3c
29 CFR 1926.1052(c)(12) · Stairways in construction
Serious$0$0Feb 2, 2004Closed

Inspection 109850602 OPENED SEP 18, 2002Closed

Follow-up · No inspection · Safety · Closed Sep 23, 2002

455 Winding Brook Drive, Glastonbury, CT 06033 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 300084902 OPENED NOV 14, 2001Closed

Unprogrammed related · Partial · Safety · 8 employees at the site · Closed Sep 25, 2002

455 Winding Brook Drive, Glastonbury, CT 06033 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$750Feb 27, 2002Closed
Citation 1, item 1b
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$0$0Feb 27, 2002Closed
Citation 1, item 1c
29 CFR 1926.502(b)(9) · Fall protection systems
Serious$0$0Feb 27, 2002Closed
Citation 1, item 2
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$1,050$525Feb 27, 2002Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(b)(1)

(1) Except during stairway construction, foot traffic is prohibited on stairways with pan stairs where the treads and/or landings are to be filled in with concrete or other material at a later date, unless the stairs are temporarily fitted with wood or other solid material at least to the top edge of each pan. Such temporary treads and landings shall be replaced when worn below the level of the top edge of the pan.

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.1052(c)(12)

(12) Unprotected sides and edges of stairway landings shall be provided with guardrail systems. Guardrail system criteria are contained in subpart M of this part.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other poured concrete foundation and structure contractors employers in Connecticut

Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.