OSHA SearchOSHA records by employer

Hopi Contracting Inc.: OSHA inspections and violations

Covington, Georgia · All Other Miscellaneous Fabricated Metal Product Manufacturing · NAICS 332999

2inspections
6citation items
$2,856current penalties
Aug 11, 2020last inspection

OSHA has inspected Hopi Contracting Inc. 2 times in Georgia since 1999.

The latest one began on Aug 11, 2020 on a referral, in Covington.

Those inspections ended with 6 citation items: 1 serious and 5 other-than-serious.

Penalties were first proposed at $4,026 and now stand at $2,856, 29% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Hopi Contracting Inc. averages $2,731 (1 cited inspection).

It reported 1 severe injury to OSHA since 2015.

Hopi Contracting Inc.: OSHA citation items per year, 1999 to 2020
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

147employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Hopi Contracting Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344882964 OPENED AUG 11, 2020Closed

Referral · Complete · Safety · 12 employees at the site · Closed Mar 9, 2021

7167 Washington St., Covington, GA 30014 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jul 28, 2020: Employee amputates finger when glove is caught by sander

At 11:00 a.m. on July 28, 2020, an employee was deburring a piece of metal when the employee's glove got caught by a sander. The employee's finger was pulled between the sander and the table rest as a result. The employee amputated his finger to the first knuckle and required medical treatment. The employee was not hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.39(a)(2) · Reporting deaths and severe injuries
Other-than-serious$3,901$2,731Jan 26, 2021Final

Inspection 302372560 OPENED FEB 5, 1999Closed

Planned · Complete · Health · 16 employees at the site · Closed Mar 15, 1999

7167 Washington Street, Covington, GA 30014 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$125$125Mar 3, 1999Closed
Citation 2, item 1
29 CFR 1910.145(c)(1) · Specifications for accident prevention signs and tags
Other-than-serious$0$0Mar 3, 1999Closed
Citation 2, item 2
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Other-than-serious$0$0Mar 3, 1999Closed
Citation 2, item 3
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Other-than-serious$0$0Mar 3, 1999Closed
Citation 2, item 4
29 CFR 1910.305(j)(1)(i) · Electrical wiring methods
Other-than-serious$0$0Mar 3, 1999Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jul 28, 2020, Covington: Amputation · amputations · fingertip(s)

An employee was operating a bench disk sander. The sander amputated the tip of the employee's ring finger.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.39 · Reporting deaths and severe injuries

29 CFR 1904.39(a)(2)

(2) Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA.

29 CFR 1910.145 · Specifications for accident prevention signs and tags

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.253(b)(2)(iv)

(iv) Valve protection caps, where cylinder is designed to accept a cap, shall always be in place, hand-tight, except when cylinders are in use or connected for use.

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(j)(1)(i)

(j) Equipment for general use—(1) Lighting fixtures, lampholders, lamps, and receptacles. (i) Fixtures, lampholders, lamps, rosettes, and receptacles may have no live parts normally exposed to employee contact. However, rosettes and cleat-type lampholders and receptacles located at least 2.44 m (8.0 ft) above the floor may have exposed terminals.

Other all other miscellaneous fabricated metal product manufacturing employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.