OSHA SearchOSHA records by employer

Horne Construction Corp.: OSHA inspections and violations

North Andover, Massachusetts · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

3inspections
13citation items
$49,307current penalties
Aug 15, 2018last inspection

Since 2011, OSHA inspectors have visited Horne Construction Corp. in Massachusetts 3 times.

The most recent inspection opened on Aug 15, 2018 as a planned inspection, in Middleton.

In all, OSHA issued 13 citation items: 12 serious and 1 repeat.

The proposed penalties came to $68,887; today they stand at $49,307, 28% less.

The rule cited most here is 1926.1053 (ladders in construction), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Horne Construction Corp. averages $37,507 across 1 cited inspection.

Horne Construction Corp.: OSHA citation items per year, 2011 to 2018
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

247employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Horne Construction Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343385878 OPENED AUG 15, 2018Closed

Planned · Partial · Safety · 5 employees at the site · Closed Nov 13, 2020

221 South Main Street, Middleton, MA 01949 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(1) · Tools—Hand and Power: general requirements
Serious$3,880$3,880Oct 23, 2018Final
Citation 1, item 2
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$3,880$3,880Oct 23, 2018Final
Citation 1, item 3a
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$3,880$3,880Oct 23, 2018Final
Citation 1, item 3b
29 CFR 1926.1053(b)(6) · Ladders in construction
Serious$0$0Oct 23, 2018Final
Citation 2, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$25,867$25,867Oct 23, 2018Final

Inspection 315860338 OPENED SEP 13, 2011Closed

Planned · Complete · Safety · 5 employees at the site · Closed May 6, 2013

152 Water Street, Danvers, MA 01923 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$3,300$1,500Dec 30, 2011Closed
Citation 1, item 2a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,620$2,000Dec 30, 2011Closed
Citation 1, item 2b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Dec 30, 2011Closed
Citation 1, item 2c
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,620$0Dec 30, 2011Closed
Citation 2, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$9,240$5,000Dec 30, 2011Closed

Inspection 315486621 OPENED APR 29, 2011Closed

Planned · Partial · Safety · 4 employees at the site · Closed Aug 9, 2011

Empire Drive Lot 1, North Andover, MA 01845 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,200$2,100Jun 28, 2011Closed
Citation 1, item 2a
29 CFR 1926.1053(b)(15) · Ladders in construction
Serious$2,400$1,200Jun 28, 2011Closed
Citation 1, item 2b
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$3,000$0Jun 28, 2011Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(15)

(15) Ladders shall be inspected by a competent person for visible defects on a periodic basis and after any occurrence that could affect their safe use.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

Other new multifamily housing construction (except for-sale builders) employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.