OSHA SearchOSHA records by employer

Houston Global Heat Transfer LLC: OSHA inspections and violations

Humble, Texas · Power Boiler and Heat Exchanger Manufacturing · NAICS 332410

1inspections
1citation items
$2,748current penalties
May 17, 2018last inspection

Houston Global Heat Transfer LLC has one OSHA inspection on record in Texas.

OSHA opened it on May 17, 2018 after a complaint, in Humble.

From that inspection OSHA issued 1 citation item: 1 other-than-serious.

OSHA proposed $5,497 in penalties. After settlements and reviews the total is $2,748, down 50%.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Houston Global Heat Transfer LLC averages $2,748 over 1 cited inspection in that time.

Houston Global Heat Transfer LLC also files yearly injury logs with OSHA, summarized below.

Houston Global Heat Transfer LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Houston Global Heat Transfer LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343165528 OPENED MAY 17, 2018Closed

Complaint · Partial · Safety · 84 employees at the site · Closed Sep 10, 2018

14446 Smith Rd., Humble, TX 77396 · Power Boiler and Heat Exchanger Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Other-than-serious$5,497$2,748Aug 10, 2018Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2017, the Humble site logged 1 recordable injury or illness among about 75 workers: 1.4 per 100 full-time workers, against a median of 2.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Houston Global Heat Transfer, LLC
Humble · 2017
75 101.42.8

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.28(b)(1)(i)

(b) Protection from fall hazards—(1) Unprotected sides and edges. (i) Except as provided elsewhere in this section, the employer must ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the following:

Other power boiler and heat exchanger manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.