OSHA SearchOSHA records by employer

Howard Finishing LLC: OSHA inspections and violations

Madison Heights, Michigan · Electroplating, Plating, Polishing, Anodizing, and Coloring · NAICS 332813

19inspections
93citation items
$73,445current penalties
Mar 7, 2018last inspection

Howard Finishing LLC has 19 OSHA inspections on record in Michigan, the first in 2007.

OSHA's last visit started on Mar 7, 2018 to monitor an earlier case, in Madison Heights.

Across those inspections OSHA issued 93 citation items: 58 serious, 9 repeat and 26 other-than-serious.

OSHA proposed $143,900 in penalties. After settlements and reviews the total is $73,445, down 49%.

Most often, OSHA cited 1910.146, permit-required confined spaces (15 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Howard Finishing LLC averages $11,867 over 3 cited inspections in that time.

Howard Finishing LLC: OSHA citation items per year, 2007 to 2018
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

665employers cited

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Howard Finishing LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342996410 OPENED MAR 7, 2018Closed

Monitoring · Partial · Health · 90 employees at the site · Closed Apr 24, 2018

32565 Dequindre Rd, Madison Heights, MI 48071 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342489366 OPENED JUL 25, 2017Closed

Planned · Complete · Health · 90 employees at the site · Closed Aug 15, 2018

32565 Dequindre Rd, Madison Heights, MI 48071 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$3,500$1,750Jan 4, 2018Final
Citation 1, item 1b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Jan 4, 2018Final
Citation 1, item 1c
29 CFR 1910.1200(h)(2) · Hazard communication
Serious$0$0Jan 4, 2018Final
Citation 1, item 2a
29 CFR 325.52503(1)
Serious$2,800$1,400Jan 4, 2018Final
Citation 1, item 2b
29 CFR 325.52504(3)
Serious$0$0Jan 4, 2018Final
Citation 1, item 2c
29 CFR 325.52504(7)
Serious$0$0Jan 4, 2018Final
Citation 1, item 3a
29 CFR 325.60114
Serious$5,600$2,800Jan 4, 2018Final
Citation 1, item 3b
29 CFR 325.60121(3)
Serious$0$0Jan 4, 2018Final
Citation 1, item 3c
29 CFR 325.60123(2)
Serious$0$0Jan 4, 2018Final
Citation 1, item 3d
29 CFR 325.60124(1)
Serious$0$0Jan 4, 2018Final
Citation 1, item 4a
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Serious$5,600$2,800Jan 4, 2018Final
Citation 1, item 4b
29 CFR 1910.146(c)(3) · Permit-required confined spaces
Serious$0$0Jan 4, 2018Final
Citation 1, item 5
29 CFR 1910.146(d)(1) · Permit-required confined spaces
Serious$5,600$2,800Jan 4, 2018Final
Citation 1, item 6
29 CFR 408.10034(7)
Serious$2,800$1,400Jan 4, 2018Final
Citation 2, item 1a
29 CFR 408.11115(1)
Repeat$6,400$3,200Jan 4, 2018Final
Citation 2, item 1b
29 CFR 408.11115(4)
Repeat$0$0Jan 4, 2018Final
Citation 2, item 2
29 CFR 325.47201(3)
Repeat$8,000$4,000Jan 4, 2018Final
Citation 2, item 3
29 CFR 1910.146(c)(2) · Permit-required confined spaces
Repeat$8,000$4,000Jan 4, 2018Final
Citation 2, item 4
29 CFR 1910.1200(f)(6) · Hazard communication
Repeat$8,000$4,000Jan 4, 2018Final
Citation 3, item 1a
29 CFR 4201(1)(C)(II)
Other-than-serious$0$0Jan 4, 2018Final
Citation 3, item 1b
29 CFR 4201(4)(B)(III)
Other-than-serious$0$0Jan 4, 2018Final
Citation 3, item 2a
29 CFR 408.22115(1)
Other-than-serious$700$350Jan 4, 2018Final
Citation 3, item 2b
29 CFR 408.22129(1)
Other-than-serious$0$0Jan 4, 2018Final

Inspection 341796282 OPENED SEP 28, 2016Closed

Referral · Partial · Safety · 116 employees at the site · Closed Oct 7, 2016

32565 Dequindre Rd, Madison Heights, MI 48071 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.12185
Serious$5,600$5,600Oct 7, 2016Final

Inspection 340187988 OPENED MAY 24, 2016Closed

Planned · Complete · Safety · 80 employees at the site · Closed Aug 22, 2016

15765 Sturgeon, Roseville, MI 48066 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.11116(1)
Serious$900$450Jul 7, 2016Final
Citation 1, item 2
29 CFR 408.15815(1)
Serious$900$450Jul 7, 2016Final
Citation 1, item 3
29 CFR 408.15836(1)
Serious$1,200$600Jul 7, 2016Final
Citation 2, item 1
29 CFR 408.10213(2)
Other-than-serious$0$0Jul 7, 2016Final
Citation 2, item 2
29 CFR 408.10835(3)
Other-than-serious$0$0Jul 7, 2016Final
Citation 2, item 3
29 CFR 408.11223(1)
Other-than-serious$0$0Jul 7, 2016Final
Citation 2, item 4
29 CFR 408.12131(1)
Other-than-serious$0$0Jul 7, 2016Final
Citation 2, item 5
29 CFR 408.12161(1)(A)
Other-than-serious$0$0Jul 7, 2016Final
Citation 2, item 6
29 CFR 408.12176(1)
Other-than-serious$0$0Jul 7, 2016Final
Citation 2, item 7
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 7, 2016Final

Inspection 340012434 OPENED NOV 18, 2015Open

Referral · Partial · Health · 90 employees at the site · Open

15765 Sturgeon, Roseville, MI 48066 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 341004869 OPENED NOV 18, 2015Closed

Referral · Partial · Health · 90 employees at the site · Closed Sep 30, 2016

15765 Sturgeon, Roseville, MI 48066 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312033509 OPENED MAR 2, 2015Closed

Follow-up · Partial · Safety · 147 employees at the site · Closed Aug 18, 2017

32565 Dequindre, Madison Heights, MI 48071 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339924508 OPENED AUG 22, 2014Closed

Complaint · Partial · Safety · 238 employees at the site · Closed Dec 15, 2014

32565 Dequindre Rd, Madison Heights, MI 48071 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.10011(A)
Serious$2,100$1,050Oct 8, 2014Final
Citation 1, item 2
29 CFR 408.13308(1)
Serious$2,100$1,050Oct 8, 2014Final
11 older inspections

Inspection 315406124 OPENED DEC 27, 2013Closed

Complaint · Partial · Health · 85 employees at the site · Closed Sep 30, 2014

15765 Sturgeon St, Roseville, MI 48066 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$2,000$1,000Apr 2, 2014Closed
Citation 1, item 1b Serious$0$0Apr 2, 2014Closed
Citation 2, item 1 Other-than-serious$0$0Apr 2, 2014Closed

Inspection 315406108 OPENED DEC 9, 2013Closed

Planned · Complete · Health · 215 employees at the site · Closed Apr 22, 2015

32565 Dequindre Rd, Madison Heights, MI 48071 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$5,000$2,000Mar 3, 2014Closed
Citation 1, item 2a Serious$3,150$1,575Mar 3, 2014Closed
Citation 1, item 2b Serious$0$0Mar 3, 2014Closed
Citation 1, item 3 Serious$3,150$1,260Mar 3, 2014Closed
Citation 2, item 1 Repeat$12,500$5,000Mar 3, 2014Closed
Citation 2, item 2
29 CFR 1910.1200(f)(6) · Hazard communication
Repeat$12,500$5,000Mar 3, 2014Closed

Inspection 315399998 OPENED APR 3, 2013Closed

Planned · Partial · Safety · 96 employees at the site · Closed Dec 16, 2013

15765 Sturgeon St, Roseville, MI 48066 · Professional Employer Organizations · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(7)(ia) · Lockout/tagout
Serious$2,800$1,400Apr 30, 2013Final
Citation 1, item 1b
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$0$0Apr 30, 2013Final
Citation 1, item 1c
29 CFR 1910.147(c)(2)(iii) · Lockout/tagout
Serious$0$0Apr 30, 2013Final

Inspection 315400549 OPENED APR 1, 2013Closed

Planned · Partial · Safety · 168 employees at the site · Closed Aug 18, 2017

32565 Dequindre, Madison Heights, MI 48071 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$5,000$3,000Jul 11, 2013Final
Citation 1, item 4a
29 CFR 1910.146(c)(2) · Permit-required confined spaces
Serious$5,000$3,000Jul 11, 2013Final
Citation 1, item 4b
29 CFR 1910.146(c)(4) · Permit-required confined spaces
Serious$0$0Jul 11, 2013Final
Citation 1, item 8a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$0$1,350Jul 11, 2013Final
Citation 1, item 8b
29 CFR 1910.147(c)(7)(ia) · Lockout/tagout
Serious$0$0Jul 11, 2013Final
Citation 1, item 9a
29 CFR 1910.146(d)(2) · Permit-required confined spaces
Serious$5,000$3,000Jul 11, 2013Final
Citation 1, item 9b
29 CFR 1910.146(d)(3) · Permit-required confined spaces
Serious$0$0Jul 11, 2013Final
Citation 1, item 9c
29 CFR 1910.146(d)(4) · Permit-required confined spaces
Serious$0$0Jul 11, 2013Final
Citation 1, item 9d
29 CFR 1910.146(d)(5)(i) · Permit-required confined spaces
Serious$0$0Jul 11, 2013Final
Citation 1, item 9e
29 CFR 1910.146(d)(5)(ii) · Permit-required confined spaces
Serious$0$0Jul 11, 2013Final
Citation 1, item 9f
29 CFR 1910.146(d)(8) · Permit-required confined spaces
Serious$0$0Jul 11, 2013Final
Citation 1, item 9g
29 CFR 1910.146(d)(9) · Permit-required confined spaces
Serious$0$0Jul 11, 2013Final
Citation 1, item 9h
29 CFR 1910.146(e)(1) · Permit-required confined spaces
Serious$0$0Jul 11, 2013Final
Citation 1, item 9i
29 CFR 1910.146(g)(1) · Permit-required confined spaces
Serious$0$0Jul 11, 2013Final
Citation 2, item 1 Other-than-serious$900$0Jul 11, 2013Final

Inspection 315403576 OPENED MAR 27, 2013Closed

Unprogrammed related · Partial · Health · 85 employees at the site · Closed Sep 16, 2013

15765 Sturgeon St, Roseville, MI 48066 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315388454 OPENED DEC 19, 2012Closed

Complaint · No inspection · Health · Closed Apr 25, 2013

15765 Sturgeon St, Roseville, MI 48066 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315382747 OPENED APR 27, 2012Closed

Complaint · Partial · Health · 156 employees at the site · Closed Sep 7, 2012

32565 Dequindre, Madison Heights, MI 48071 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,500$750Jul 19, 2012Closed
Citation 1, item 2
29 CFR 1910.1200(f)(5) · Hazard communication
Serious$1,500$600Jul 19, 2012Closed
Citation 1, item 3
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$1,500$750Jul 19, 2012Closed
Citation 1, item 4 Serious$1,200$480Jul 19, 2012Closed
Citation 1, item 5 Serious$1,500$600Jul 19, 2012Closed
Citation 2, item 1
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Jul 19, 2012Closed
Citation 2, item 2 Other-than-serious$0$0Jul 19, 2012Closed
Citation 2, item 3 Other-than-serious$0$0Jul 19, 2012Closed

Inspection 312005424 OPENED MAY 16, 2011Closed

Planned · Complete · Safety · 60 employees at the site · Closed Jul 19, 2011

15765 Sturgeon St, Roseville, MI 48066 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,000$400Jun 10, 2011Closed
Citation 1, item 2 Serious$1,750$700Jun 10, 2011Closed
Citation 1, item 3
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$1,000$400Jun 10, 2011Closed
Citation 2, item 1 Other-than-serious$0$0Jun 10, 2011Closed
Citation 2, item 2
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Other-than-serious$0$0Jun 10, 2011Closed
Citation 2, item 3
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Jun 10, 2011Closed
Citation 2, item 4 Other-than-serious$0$0Jun 10, 2011Closed
Citation 2, item 5 Other-than-serious$0$0Jun 10, 2011Closed
Citation 2, item 6
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0Jun 10, 2011Closed

Inspection 311999320 OPENED NOV 30, 2010Closed

Planned · Complete · Safety · 125 employees at the site · Closed Feb 8, 2011

32565 Dequindre Rd, Madison Heights, MI 48071 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Repeat$900$900Dec 29, 2010Closed
Citation 1, item 2 Repeat$2,400$1,440Dec 29, 2010Closed

Inspection 308805985 OPENED JUL 22, 2009Closed

Planned · Complete · Safety · 90 employees at the site · Closed Sep 16, 2009

32565 Dequindre Rd, Madison Heights, MI 48071 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$450$180Aug 18, 2009Closed
Citation 1, item 2 Serious$450$180Aug 18, 2009Closed
Citation 1, item 3a Serious$450$180Aug 18, 2009Closed
Citation 1, item 3b Serious$0$0Aug 18, 2009Closed
Citation 1, item 4 Serious$600$240Aug 18, 2009Closed
Citation 1, item 5 Serious$450$180Aug 18, 2009Closed
Citation 1, item 6
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$450$180Aug 18, 2009Closed
Citation 2, item 1 Other-than-serious$0$0Aug 18, 2009Closed
Citation 2, item 2 Other-than-serious$0$0Aug 18, 2009Closed
Citation 2, item 3 Other-than-serious$0$0Aug 18, 2009Closed
Citation 2, item 4 Other-than-serious$0$0Aug 18, 2009Closed

Inspection 308869247 OPENED MAR 20, 2007Closed

Planned · No inspection · Health · Closed Mar 28, 2007

32565 Dequindre, Madison Heights, MI 48071 · All Other Miscellaneous Chemical Product and Preparation Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(f)(5)

(f) Any organic peroxide which, in laboratory testing, neither detonates in the cavitated state nor deflagrates at all and shows only a low or no effect when heated under confinement as well as low or no explosive power shall be defined as organic peroxide TYPE F;

29 CFR 1910.1200(f)(5)(i)

(5) Transportation. (i) Chemical manufacturers, importers, or distributors shall ensure that each container of hazardous chemicals leaving the workplace is labeled, tagged, or marked in accordance with this section in a manner which does not conflict with the requirements of the Hazardous Materials Transportation Act (49 U.S.C. 5101 et seq.) and regulations issued under that Act by the Department of Transportation (49 CFR subtitle B).

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 3254.7201

29 CFR 3255.1455

29 CFR 3255.1472

29 CFR 3256.5

29 CFR 3256.8

29 CFR 4080.1014

29 CFR 4081.11

29 CFR 4081.1115

29 CFR 4081.125

29 CFR 4081.15

29 CFR 4081.21

29 CFR 4081.213

29 CFR 4081.2176

29 CFR 4081.219

29 CFR 4081.232

29 CFR 4081.2635

29 CFR 4081.2732

29 CFR 4081.34

29 CFR 4081.4007

29 CFR 4081.4965

29 CFR 4081.632

29 CFR 4081.685

29 CFR 4081.727

29 CFR 4081.731

29 CFR 4082.2129

29 CFR 4082.2140

Other electroplating, plating, polishing, anodizing, and coloring employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.