OSHA SearchOSHA records by employer

HST Contruction, Inc.: OSHA inspections and violations

Fajardo, Puerto Rico · Water and Sewer Line and Related Structures Construction · NAICS 237110

1inspections
3citation items
$3,000current penalties
Jan 25, 2016last inspection

HST Contruction, Inc. has one OSHA inspection on record in Puerto Rico.

OSHA opened it on Jan 25, 2016 as a planned inspection, in Fajardo.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $4,000 in penalties. After settlements and reviews the total is $3,000, down 25%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. HST Contruction, Inc. averages $3,000 over 1 cited inspection in that time.

HST Contruction, Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Puerto Rico · latest 90 days of OSHA records

109employers cited

Get notified the morning OSHA posts each new citation in Puerto Rico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Puerto Rico

Checking a subcontractor, a client or your own company? Watch HST Contruction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341212983 OPENED JAN 25, 2016Closed

Planned · Partial · Safety · 25 employees at the site · Closed Oct 26, 2016

Puerto Del Rey Marina, Fajardo, PR 00738 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.28(a) · Personal protective equipment
Serious$1,200$900Jun 21, 2016Final
Citation 1, item 2
29 CFR 1926.150(c)(1)(vi) · Fire protection
Serious$1,200$900Jun 21, 2016Final
Citation 1, item 3
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$1,600$1,200Jun 21, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(vi)

(vi) A fire extinguisher, rated not less than 10B, shall be provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas are being used on the jobsite. This requirement does not apply to the integral fuel tanks of motor vehicles.

29 CFR 1926.28 · Personal protective equipment

29 CFR 1926.28(a)

(a) The employer is responsible for requiring the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions or where this part indicates the need for using such equipment to reduce the hazards to the employees.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

Other water and sewer line and related structures construction employers in Puerto Rico

Alert subscribers get notified of each newly cited employer in Puerto Rico the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.