OSHA SearchOSHA records by employer

Hutcherson Metals, Inc.: OSHA inspections and violations

North Syracuse, New York · All Other Specialty Trade Contractors · NAICS 238990

2inspections
29citation items
$35,280current penalties
Oct 7, 2015last inspection

OSHA has inspected Hutcherson Metals, Inc. 2 times in New York since 2015.

The latest one began on Oct 7, 2015 on a referral, in North Syracuse.

Those inspections ended with 29 citation items: 29 serious.

Penalties were first proposed at $58,800 and now stand at $35,280, 40% lower after settlements or reviews.

Lead in construction comes up most often in these citations: 15 items under 1926.62.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Hutcherson Metals, Inc. averages $17,640 (2 cited inspections).

Hutcherson Metals, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Hutcherson Metals, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340968031 OPENED OCT 7, 2015Closed

Referral · Complete · Safety · 3 employees at the site · Closed Oct 30, 2017

510 Stewart Drive Building 503, North Syracuse, NY 13212 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(b)(1) · Eye and face protection in construction
Serious$2,800$1,680Nov 24, 2015Final
Citation 1, item 2
29 CFR 1926.150(a)(4) · Fire protection
Serious$2,100$1,260Nov 24, 2015Final
Citation 1, item 3
29 CFR 1926.350(j) · Gas welding and cutting
Serious$2,800$1,680Nov 24, 2015Final
Citation 1, item 4a
29 CFR 1926.403(b)(1) · Electrical equipment on job sites
Serious$3,500$2,100Nov 24, 2015Final
Citation 1, item 4b
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$0$0Nov 24, 2015Final
Citation 1, item 4c
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Nov 24, 2015Final
Citation 1, item 5
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$3,500$2,100Nov 24, 2015Final
Citation 1, item 6a
29 CFR 1926.451(c)(2)(iv) · Scaffolds, general requirements
Serious$2,800$1,680Nov 24, 2015Final
Citation 1, item 6b
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Serious$0$0Nov 24, 2015Final
Citation 1, item 7a
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$3,500$2,100Nov 24, 2015Final
Citation 1, item 7b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Nov 24, 2015Final

Inspection 340968056 OPENED OCT 7, 2015Closed

Referral · Partial · Health · 3 employees at the site · Closed Oct 18, 2017

510 Stewart Drive Building 503, North Syracuse, NY 13212 · Recyclable Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.55(a) · Gases, vapors, fumes, dusts, and mists
Serious$4,200$2,520Nov 24, 2015Final
Citation 1, item 1b
29 CFR 1926.55(b) · Gases, vapors, fumes, dusts, and mists
Serious$0$0Nov 24, 2015Final
Citation 1, item 2a
29 CFR 1926.62(c)(1) · Lead in construction
Serious$4,200$2,520Nov 24, 2015Final
Citation 1, item 2b
29 CFR 1926.62(e)(1) · Lead in construction
Serious$0$0Nov 24, 2015Final
Citation 1, item 3a
29 CFR 1926.62(d)(1)(i) · Lead in construction
Serious$4,200$2,520Nov 24, 2015Final
Citation 1, item 3b
29 CFR 1926.62(d)(1)(iii) · Lead in construction
Serious$0$0Nov 24, 2015Final
Citation 1, item 4a
29 CFR 1926.62(d)(2)(v)(a) · Lead in construction
Serious$4,200$2,520Nov 24, 2015Final
Citation 1, item 4b
29 CFR 1926.62(f)(1) · Lead in construction
Serious$0$0Nov 24, 2015Final
Citation 1, item 4c
29 CFR 1910.134(c) · Respiratory protection
Serious$0$0Nov 24, 2015Final
Citation 1, item 5a
29 CFR 1926.62(d)(2)(v)(c) · Lead in construction
Serious$4,200$2,520Nov 24, 2015Final
Citation 1, item 5b
29 CFR 1926.62(i)(2)(i) · Lead in construction
Serious$0$0Nov 24, 2015Final
Citation 1, item 6a
29 CFR 1926.62(d)(2)(v)(d) · Lead in construction
Serious$4,200$2,520Nov 24, 2015Final
Citation 1, item 6b
29 CFR 1926.62(i)(5)(i) · Lead in construction
Serious$0$0Nov 24, 2015Final
Citation 1, item 7a
29 CFR 1926.62(d)(2)(v)(e) · Lead in construction
Serious$4,200$2,520Nov 24, 2015Final
Citation 1, item 7b
29 CFR 1926.62(j)(1)(i) · Lead in construction
Serious$0$0Nov 24, 2015Final
Citation 1, item 8a
29 CFR 1926.62(d)(2)(v)(f) · Lead in construction
Serious$4,200$2,520Nov 24, 2015Final
Citation 1, item 8b
29 CFR 1926.62(l)(1)(ii) · Lead in construction
Serious$0$0Nov 24, 2015Final
Citation 1, item 9
29 CFR 1926.62(e)(2)(i) · Lead in construction
Serious$4,200$2,520Nov 24, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)

(c) After completing the test exercises, the test administrator must question each test subject regarding the comfort of the respirator. When a test subject states that the respirator is unacceptable, the employer must ensure that the test administrator repeats the protocol using another respirator model.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(b)(1)

(b) Criteria for protective eye and face protection. (1) Protective eye and face protection devices must comply with any of the following consensus standards:

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(a)(4)

(4) All firefighting equipment shall be periodically inspected and maintained in operating condition. Defective equipment shall be immediately replaced.

29 CFR 1926.350 · Gas welding and cutting

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.55 · Gases, vapors, fumes, dusts, and mists

29 CFR 1926.62 · Lead in construction

Other all other specialty trade contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.