OSHA SearchOSHA records by employer

HV Masonry, LLC.: OSHA inspections and violations

New Albany, Ohio · Masonry Contractors · NAICS 238140

1inspections
4citation items
$7,200current penalties
Mar 16, 2016last inspection

OSHA has inspected HV Masonry, LLC. once in Ohio.

The inspection began on Mar 16, 2016 as a planned inspection, in New Albany.

That inspection ended with 4 citation items: 3 serious and 1 other-than-serious.

Penalties were first proposed at $7,200 and still stand at $7,200.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and HV Masonry, LLC. averages $7,200 (1 cited inspection).

HV Masonry, LLC.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

267employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch HV Masonry, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341334159 OPENED MAR 16, 2016Closed

Planned · Complete · Safety · 5 employees at the site · Closed Apr 11, 2023

4 Ealy Crossing, New Albany, OH 43054 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$2,000$2,000Apr 6, 2016Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$2,000$2,000Apr 6, 2016Final
Citation 1, item 3
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,800$2,800Apr 6, 2016Final
Citation 2, item 1
29 CFR 1903.19(d)(1) · Proving cited hazards were fixed
Other-than-serious$400$400Jun 1, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(d)(1)

(d) Abatement documentation. (1) The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.501 · Fall protection in construction

Other masonry contractors employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.