OSHA SearchOSHA records by employer

I & a Development LLC: OSHA inspections and violations

San Antonio, Texas · Masonry Contractors · NAICS 238140

1inspections
3citation items
$8,894current penalties
Mar 2, 2021last inspection

OSHA has inspected I & a Development LLC once in Texas.

The inspection began on Mar 2, 2021, in San Antonio.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $14,823 and now stand at $8,894, 40% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and I & a Development LLC averages $8,894 (1 cited inspection).

I & a Development LLC: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch I & a Development LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345182000 OPENED MAR 2, 2021Closed

Unprogrammed other · Partial · Safety · 8 employees at the site · Closed Aug 9, 2021

2214 Tpc Pkwy, San Antonio, TX 78258 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(2)(iii) · Scaffolds, general requirements
Serious$3,901$2,341Jun 23, 2021Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(iv) · Scaffolds, general requirements
Serious$5,461$3,277Jun 23, 2021Final
Citation 1, item 3
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$5,461$3,277Jun 23, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(2)(iii)

(iii) When hook-on and attachable ladders are used on a supported scaffold more than 35 feet (10.7 m) high, they shall have rest platforms at 35-foot (10.7 m) maximum vertical intervals.

29 CFR 1926.451(g)(4)(iv)

(iv) When midrails are used, they shall be installed at a height approximately midway between the top edge of the guardrail system and the platform surface.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(c)(2)

(2) Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured.