OSHA SearchOSHA records by employer

I & M Stucco: OSHA inspections and violations

Tulsa, Oklahoma · Drywall and Insulation Contractors · NAICS 238310

3inspections
17citation items
$25,530current penalties
Dec 1, 2015last inspection

OSHA has inspected I & M Stucco 3 times in Oklahoma since 2009.

The latest one began on Dec 1, 2015 as a planned inspection, in Tulsa.

Those inspections ended with 17 citation items: 15 serious and 2 repeat.

Penalties were first proposed at $25,530 and still stand at $25,530.

Scaffolds, general requirements comes up most often in these citations: 14 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and I & M Stucco averages $14,400 (1 cited inspection).

I & M Stucco: OSHA citation items per year, 2009 to 2015
Citation items per year, by inspection date.

Oklahoma · latest 90 days of OSHA records

52employers cited

Get notified the morning OSHA posts each new citation in Oklahoma: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oklahoma

Checking a subcontractor, a client or your own company? Watch I & M Stucco and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341096691 OPENED DEC 1, 2015Closed

Planned · Partial · Safety · 7 employees at the site · Closed Apr 16, 2019

1331 E. 71st St., Tulsa, OK 74136 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Repeat$5,600$5,600Feb 17, 2016Final
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$5,600$5,600Feb 17, 2016Final
Citation 2, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$1,200$1,200Feb 17, 2016Final
Citation 2, item 2a
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$2,000$2,000Feb 17, 2016Final
Citation 2, item 2b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Feb 17, 2016Final

Inspection 314934605 OPENED AUG 29, 2011Closed

Planned · Partial · Safety · 2 employees at the site · Closed Sep 30, 2012

7547 S. Olympia Ave. West, Tulsa, OK 74132 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Serious$3,780$3,780Oct 19, 2011Closed
Citation 1, item 1b
29 CFR 1926.451(c)(2)(iii) · Scaffolds, general requirements
Serious$0$0Oct 19, 2011Closed
Citation 1, item 2a
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$2,700$2,700Oct 19, 2011Closed
Citation 1, item 2b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Oct 19, 2011Closed
Citation 1, item 3a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$2,700$2,700Oct 19, 2011Closed
Citation 1, item 3b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Oct 19, 2011Closed

Inspection 313686446 OPENED SEP 23, 2009Closed

Planned · Partial · Safety · 10 employees at the site · Closed Jun 13, 2012

17 W 7th St., Tulsa, OK 74119 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$750$750Nov 4, 2009Closed
Citation 1, item 1b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Nov 4, 2009Closed
Citation 1, item 2a
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$450$450Nov 4, 2009Closed
Citation 1, item 2b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Nov 4, 2009Closed
Citation 1, item 3a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$750$750Nov 4, 2009Closed
Citation 1, item 3b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Nov 4, 2009Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)(i)

(i) Footings shall be level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.

29 CFR 1926.454 · Scaffold training

Other drywall and insulation contractors employers in Oklahoma

Alert subscribers get notified of each newly cited employer in Oklahoma the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.