OSHA SearchOSHA records by employer

I Diamond I Siding: OSHA inspections and violations

Bismarck, North Dakota · Siding Contractors · NAICS 238170

3inspections
7citation items
$3,130current penalties
Oct 31, 2018last inspection

I Diamond I Siding has 3 OSHA inspections on record in North Dakota, the first in 2003.

OSHA's last visit started on Oct 31, 2018 as a planned inspection, in Mandan.

Across those inspections OSHA issued 7 citation items: 7 serious.

OSHA proposed $5,692 in penalties. After settlements and reviews the total is $3,130, down 45%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. I Diamond I Siding averages $1,705 over 1 cited inspection in that time.

I Diamond I Siding: OSHA citation items per year, 2003 to 2018
Citation items per year, by inspection date.

North Dakota · latest 90 days of OSHA records

30employers cited

Get notified the morning OSHA posts each new citation in North Dakota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Dakota

Checking a subcontractor, a client or your own company? Watch I Diamond I Siding and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343652277 OPENED OCT 31, 2018Closed

Planned · Partial · Safety · 5 employees at the site · Closed May 29, 2019

3018 Marina Road Se, Mandan, ND 58554 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.304(d) · Woodworking tools
Serious$2,842$1,705Apr 26, 2019Final

Inspection 314700543 OPENED JUL 29, 2010Closed

Planned · Partial · Safety · 2 employees at the site · Closed Jan 13, 2011

4810 Golden Way, Bismarck, ND 58503 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$750$375Dec 14, 2010Closed
Citation 1, item 2a
29 CFR 1926.451(b)(10) · Scaffolds, general requirements
Serious$600$300Dec 14, 2010Closed
Citation 1, item 2b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Dec 14, 2010Closed
Citation 1, item 3a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$750$375Dec 14, 2010Closed
Citation 1, item 3b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Dec 14, 2010Closed

Inspection 304207905 OPENED APR 11, 2003Closed

Planned · Partial · Safety · 2 employees at the site · Closed May 20, 2003

3612 Dominion, Bismarck, ND 58501 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$750$375Apr 15, 2003Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(d)

(d) Guarding. All portable, power-driven circular saws shall be equipped with guards above and below the base plate or shoe. The upper guard shall cover the saw to the depth of the teeth, except for the minimum arc required to permit the base to be tilted for bevel cuts. The lower guard shall cover the saw to the depth of the teeth, except for the minimum arc required to allow proper retraction and contact with the work. When the tool is withdrawn from the work, the lower guard shall automatically and instantly return to the covering position.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.451(b)(10)

(10) Scaffold components manufactured by different manufacturers shall not be intermixed unless the components fit together without force and the scaffold's structural integrity is maintained by the user. Scaffold components manufactured by different manufacturers shall not be modified in order to intermix them unless a competent person determines the resulting scaffold is structurally sound.