OSHA SearchOSHA records by employer

I Q Construction Inc: OSHA inspections and violations

Kihei, Hawaii · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

1inspections
5citation items
$2,100current penalties
May 7, 2015last inspection

I Q Construction Inc has one OSHA inspection on record in Hawaii.

OSHA opened it on May 7, 2015 on a referral, in Kihei.

From that inspection OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

OSHA proposed $3,000 in penalties. After settlements and reviews the total is $2,100, down 30%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. I Q Construction Inc averages $2,100 over 1 cited inspection in that time.

I Q Construction Inc: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Hawaii · latest 90 days of OSHA records

63employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in Hawaii: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Hawaii

Checking a subcontractor, a client or your own company? Watch I Q Construction Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340643592 OPENED MAY 7, 2015Closed

Referral · Complete · Safety · 3 employees at the site · Closed Sep 17, 2015

100 Hale Alii Place, Kihei, HI 96753 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.304(i)(1) · Woodworking tools
Serious$1,050$735Jun 10, 2015Final
Citation 1, item 2a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$750$525Jun 10, 2015Final
Citation 1, item 2b
29 CFR 1926.502(b)(2) · Fall protection systems
Serious$0$0Jun 10, 2015Final
Citation 1, item 3
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$1,200$840Jun 10, 2015Final
Citation 2, item 1
29 CFR 12-110-3(C)
Other-than-serious$0$0Jun 10, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(i)(1)

(i) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.502(b)(2)

(2) Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members shall be installed between the top edge of the guardrail system and the walking/working surface when there is no wall or parapet wall at least 21 inches (53 cm) high.

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other new single-family housing construction (except for-sale builders) employers in Hawaii

Alert subscribers get notified of each newly cited employer in Hawaii the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.