OSHA SearchOSHA records by employer

Ibk Construction Group, LLC: OSHA inspections and violations

Brooklyn, New York · Poured Concrete Foundation and Structure Contractors · NAICS 238110

9inspections
18citation items
$60,468current penalties
Jan 14, 2019last inspection

Since 2008, OSHA inspectors have visited Ibk Construction Group, LLC in New York 9 times.

The most recent inspection opened on Jan 14, 2019 as part of a related case, in Mineola.

In all, OSHA issued 18 citation items: 15 serious, 2 repeat and 1 other-than-serious.

The proposed penalties came to $72,418; today they stand at $60,468, 17% less.

The rule cited most here is 1926.502 (fall protection systems), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Ibk Construction Group, LLC averages $12,539 across 3 cited inspections.

Ibk Construction Group, LLC also files yearly injury logs with OSHA, summarized below.

Ibk Construction Group, LLC: OSHA citation items per year, 2008 to 2019
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Ibk Construction Group, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343712444 OPENED JAN 14, 2019Closed

Unprogrammed related · Partial · Health · 16 employees at the site · Closed Apr 9, 2019

199 2nd Street, Mineola, NY 11501 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343625430 OPENED NOV 28, 2018Closed

Referral · Complete · Safety · 180 employees at the site · Closed Feb 15, 2019

266 Kent Ave, Brooklyn, NY 11249 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343592648 OPENED NOV 9, 2018Closed

Complaint · Partial · Safety · 208 employees at the site · Closed May 23, 2019

266 Kent Ave, Brooklyn, NY 11249 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.502(d)(15) · Fall protection systems
Serious$12,934$12,934Nov 20, 2018Final
Citation 1, item 2
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$12,934$12,934Nov 20, 2018Final

Inspection 343576625 OPENED NOV 2, 2018Closed

Referral · Records only · Safety · 25 employees at the site · Closed Dec 6, 2018

199 2nd St., Mineola, NY 11501 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.39(a)(2) · Reporting deaths and severe injuries
Other-than-serious$5,000$5,000Nov 2, 2018Final

Inspection 341173573 OPENED JAN 13, 2016Closed

Referral · Complete · Safety · 450 employees at the site · Closed Jun 21, 2016

100 Bogart St, Brooklyn, NY 11206 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(c)(1) · Fall protection in construction
Serious$4,000$3,000May 13, 2016Final
Citation 1, item 2
29 CFR 1926.502(b)(2)(iv) · Fall protection systems
Serious$5,000$3,750May 13, 2016Final

Inspection 313999864 OPENED NOV 24, 2009Closed

Unprogrammed other · Complete · Safety · 18 employees at the site · Closed Dec 22, 2009

160-162 12th Street, Brooklyn, NY 11211 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$1,200$1,200Dec 10, 2009Closed
Citation 1, item 2
29 CFR 1926.1060(a)(1) · Ladder and stairway training
Serious$1,200$1,200Dec 10, 2009Closed

Inspection 313236952 OPENED JUN 2, 2009Closed

Unprogrammed related · Complete · Safety · 56 employees at the site · Closed Jun 2, 2009

350 W 37th Street, New York, NY 10018 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313236523 OPENED MAY 6, 2009Closed

Planned · Complete · Safety · 10 employees at the site · Closed Dec 22, 2009

235 Gold St, Brooklyn, NY 11201 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(e) · Electrical equipment on job sites
Serious$2,000$1,350Aug 21, 2009Closed
Citation 1, item 2
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$2,000$1,350Aug 21, 2009Closed
Citation 1, item 3
29 CFR 1926.452(i)(6) · Rules for each type of scaffold
Serious$4,000$2,700Aug 21, 2009Closed
Citation 1, item 4
29 CFR 1926.452(i)(8) · Rules for each type of scaffold
Serious$4,000$2,700Aug 21, 2009Closed
Citation 1, item 5
29 CFR 1926.502(i)(3) · Fall protection systems
Serious$2,000$1,350Aug 21, 2009Closed
1 older inspection

Inspection 312605207 OPENED NOV 13, 2008Closed

Planned · Complete · Safety · 60 employees at the site · Closed Mar 30, 2009

424 Bedford Ave, Brooklyn, NY 11211 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,500$1,700Mar 11, 2009Closed
Citation 1, item 2
29 CFR 1926.502(d)(15) · Fall protection systems
Serious$3,000$2,000Mar 11, 2009Closed
Citation 1, item 3
29 CFR 1926.503(c) · Fall protection training in construction
Serious$1,250$760Mar 11, 2009Closed
Citation 1, item 4
29 CFR 1926.1060(b) · Ladder and stairway training
Serious$1,000$660Mar 11, 2009Closed
Citation 2, item 1
29 CFR 1926.1052(c)(1) · Stairways in construction
Repeat$2,400$1,680Mar 11, 2009Closed
Citation 2, item 2
29 CFR 1926.1052(c)(12) · Stairways in construction
Repeat$6,000$4,200Mar 11, 2009Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2019, the Brooklyn site logged 15 recordable injuries or illnesses among about 237 workers: 6.1 per 100 full-time workers, against a median of 2.8 for its industry. Those cases cost 757 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Ibk Construction Group, LLC
Brooklyn · 2019
237 15116.12.8

Included with any plan: 1 more yearly log from these sites, back to 2018, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.39 · Reporting deaths and severe injuries

29 CFR 1904.39(a)(2)

(2) Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.1052(c)(12)

(12) Unprotected sides and edges of stairway landings shall be provided with guardrail systems. Guardrail system criteria are contained in subpart M of this part.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other poured concrete foundation and structure contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.