OSHA SearchOSHA records by employer

Icf Direct Service Center Corporation: OSHA inspections and violations

Amarillo, Texas · Structural Steel and Precast Concrete Contractors · NAICS 238120

1inspections
4citation items
$3,200current penalties
Apr 7, 2015last inspection

OSHA inspectors have visited Icf Direct Service Center Corporation in Texas one time.

It opened on Apr 7, 2015 as a planned inspection, in Amarillo.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $5,860; today they stand at $3,200, 45% less.

The rule cited most here is 1910.305 (electrical wiring methods), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Icf Direct Service Center Corporation averages $3,200 across 1 cited inspection.

Icf Direct Service Center Corporation: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

394employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Icf Direct Service Center Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340523257 OPENED APR 7, 2015Closed

Planned · Complete · Safety · 3 employees at the site · Closed Jan 27, 2017

5814 Tradewind Street, Amarillo, TX 79114 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$2,040$1,122Jul 2, 2015Final
Citation 1, item 2
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$1,600$880Jul 2, 2015Final
Citation 1, item 3
29 CFR 1910.305(c)(2) · Electrical wiring methods
Serious$1,020$561Jul 2, 2015Final
Citation 1, item 4
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$1,200$637Jul 2, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.219(f)(3)

(3) Sprockets and chains. All sprocket wheels and chains shall be enclosed unless they are more than seven (7) feet above the floor or platform. Where the drive extends over other machine or working areas, protection against falling shall be provided. This subparagraph does not apply to manually operated sprockets.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1910.305(c)(2)

(2) Double-throw knife switches. Double-throw knife switches may be mounted so that the throw will be either vertical or horizontal. However, if the throw is vertical, a locking device shall be provided to ensure that the blades remain in the open position when so set.