OSHA SearchOSHA records by employer

Icon Trailers Ltd: OSHA inspections and violations

Seminole, Texas · Truck Trailer Manufacturing · NAICS 336212

1inspections
4citation items
$932current penalties
Aug 23, 2023last inspection

OSHA has inspected Icon Trailers Ltd once in Texas.

The inspection began on Aug 23, 2023 on a referral, in Seminole.

That inspection ended with 4 citation items: 4 other-than-serious.

Penalties were first proposed at $1,554 and now stand at $932, 40% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Icon Trailers Ltd averages $932 (1 cited inspection).

Icon Trailers Ltd: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Want to know if OSHA cites Icon Trailers Ltd again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346952575 OPENED AUG 23, 2023Closed

Referral · Partial · Safety · 25 employees at the site · Closed Mar 26, 2024

179 County Road 315, Seminole, TX 79360 · Truck Trailer Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(b)(2) · Exit routes
Other-than-serious$518$311Feb 14, 2024Final
Citation 1, item 2
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$518$311Feb 14, 2024Final
Citation 1, item 3
29 CFR 1910.303(e)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$518$311Feb 14, 2024Final
Citation 1, item 4
29 CFR 1910.305(a)(2)(v)(c) · Electrical wiring methods
Other-than-serious$0$0Feb 14, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(e)(2)

(2) Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(e)(1)(ii)

(ii) Other markings giving voltage, current, wattage, or other ratings as necessary.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(a)(2)(v)(c)

(C) No branch-circuit conductor may be laid on the floor.

29 CFR 1910.37 · Exit routes

Other truck trailer manufacturing employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.