Idc Industries Inc: OSHA inspections and violations
Clinton Township, Michigan · Mechanical Power Transmission Equipment Manufacturing · NAICS 333613
3inspections
14citation items
$4,900current penalties
May 28, 2024last inspection
OSHA has inspected Idc Industries Inc 3 times in Michigan since 2017.
The latest one began on May 28, 2024 on a referral, in Clinton Township.
Those inspections ended with 14 citation items: 8 serious and 6 other-than-serious.
Penalties were first proposed at $9,800 and now stand at $4,900, 50% lower after settlements or reviews.
Flammable liquids comes up most often in these citations: 2 items under 1910.106.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Idc Industries Inc averages $2,450 (2 cited inspections).
Idc Industries Inc also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Michigan · latest 90 days of OSHA records
647employers cited
Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Clinton Township site logged 1 recordable injury or illness among about 49 workers: 1.8 per 100 full-time workers, against a median of 2.1 for its industry. Those cases cost 166 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
IDC Industries, Inc.
Clinton Township · 2024
49
1
1
1.8
2.1
Included with any plan: 5 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.
29 CFR 1910.106(e)(6)(ii)
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
29 CFR 1910.303 · Electrical equipment, general requirements
29 CFR 1910.303(g)(2)(i)
(2) Guarding of live parts. (i) Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:
Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.