OSHA SearchOSHA records by employer

Ideal Construction, Inc.: OSHA inspections and violations

Philadelphia, Pennsylvania · Poured Concrete Foundation and Structure Contractors · NAICS 238110

2inspections
7citation items
$18,820current penalties
Aug 23, 2017last inspection

Since 2014, OSHA inspectors have visited Ideal Construction, Inc. in Pennsylvania 2 times.

The most recent inspection opened on Aug 23, 2017 after a complaint, in Philadelphia.

In all, OSHA issued 7 citation items: 5 serious and 2 repeat.

The proposed penalties came to $20,740; today they stand at $18,820, 9% less.

The rule cited most here is 1926.701 (concrete and masonry construction: general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Ideal Construction, Inc. averages $14,340 across 1 cited inspection.

Ideal Construction, Inc.: OSHA citation items per year, 2014 to 2017
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

285employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Ideal Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342638905 OPENED AUG 23, 2017Closed

Complaint · Partial · Safety · 10 employees at the site · Closed Jan 30, 2023

601 Christian Street, Philadelphia, PA 19147 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(k)(1) · Excavations
Serious$2,390$2,390Nov 17, 2017Final
Citation 2, item 1
29 CFR 1926.652(a)(1) · Trench protection
Repeat$7,170$7,170Nov 17, 2017Final
Citation 2, item 2
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Repeat$4,780$4,780Nov 17, 2017Final

Inspection 340102292 OPENED NOV 20, 2014Closed

Referral · Partial · Safety · 10 employees at the site · Closed Jul 24, 2015

951 N 2nd Street, Philadelphia, PA 19123 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$2,000$1,400May 11, 2015Final
Citation 1, item 2a
29 CFR 1926.652(a)(1) · Trench protection
Serious$2,800$1,960May 11, 2015Final
Citation 1, item 2b
29 CFR 1926.651(i)(3) · Excavations
Serious$0$0May 11, 2015Final
Citation 1, item 3
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$1,600$1,120May 11, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(i)(3)

(3) Sidewalks, pavements, and appurtenant structure shall not be undermined unless a support system or another method of protection is provided to protect employees from the possible collapse of such structures.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other poured concrete foundation and structure contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.