OSHA SearchOSHA records by employer

Industrial Piping and Mechanical, LLC: OSHA inspections and violations

Gordon, Georgia · Oil and Gas Pipeline and Related Structures Construction · NAICS 237120

1inspections
5citation items
$14,300current penalties
Oct 4, 2018last inspection

Industrial Piping and Mechanical, LLC has one OSHA inspection on record in Georgia.

OSHA opened it on Oct 4, 2018, in Gordon.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $25,923 in penalties. After settlements and reviews the total is $14,300, down 45%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Industrial Piping and Mechanical, LLC averages $14,300 over 1 cited inspection in that time.

Industrial Piping and Mechanical, LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

157employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Industrial Piping and Mechanical, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343514311 OPENED OCT 4, 2018Closed

Unprogrammed other · Partial · Safety · 24 employees at the site · Closed Jul 17, 2019

7400 Gordon Mcintyre Road, Gordon, GA 31031 · Oil and Gas Pipeline and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.351(e) · Arc welding and cutting
Serious$3,381$1,900Feb 5, 2019Final
Citation 1, item 2
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$5,635$3,100Feb 5, 2019Final
Citation 1, item 3
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$5,635$3,100Feb 5, 2019Final
Citation 1, item 4
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$5,636$3,100Feb 5, 2019Final
Citation 1, item 5
29 CFR 1926.452(b)(3) · Rules for each type of scaffold
Serious$5,636$3,100Feb 5, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.351 · Arc welding and cutting

29 CFR 1926.351(e)

(e) Shielding. Whenever practicable, all arc welding and cutting operations shall be shielded by noncombustible or flameproof screens which will protect employees and other persons working in the vicinity from the direct rays of the arc.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.452 · Rules for each type of scaffold

Other oil and gas pipeline and related structures construction employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.