OSHA SearchOSHA records by employer

Industrial Wire Mesh International, LLC: OSHA inspections and violations

Hanover, Pennsylvania · Steel Wire Drawing · NAICS 331222

1inspections
7citation items
$13,714current penalties
Feb 28, 2019last inspection

OSHA inspectors have visited Industrial Wire Mesh International, LLC in Pennsylvania one time.

It opened on Feb 28, 2019 as a planned inspection, in Hanover.

In all, OSHA issued 7 citation items: 4 serious and 3 other-than-serious.

The proposed penalties came to $18,286; today they stand at $13,714, 25% less.

The rule cited most here is 1910.303 (electrical equipment, general requirements), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Industrial Wire Mesh International, LLC averages $13,714 across 1 cited inspection.

Industrial Wire Mesh International, LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

274employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Industrial Wire Mesh International, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343824256 OPENED FEB 28, 2019Closed

Planned · Complete · Safety · 164 employees at the site · Closed Apr 5, 2019

500 East Middle Street, Hanover, PA 17331 · Steel Wire Drawing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Serious$5,626$4,220Mar 21, 2019Final
Citation 1, item 2
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$4,220$3,165Mar 21, 2019Final
Citation 1, item 3
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$4,220$3,165Mar 21, 2019Final
Citation 1, item 4
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$4,220$3,165Mar 21, 2019Final
Citation 2, item 1
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Mar 21, 2019Final
Citation 2, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Mar 21, 2019Final
Citation 2, item 3
29 CFR 1910.303(e)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Mar 21, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

29 CFR 1910.303(b)(7)(i)

(i) Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment.

29 CFR 1910.305 · Electrical wiring methods

Other steel wire drawing employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.