Inspection 344362512 OPENED OCT 8, 2019Closed
20919 Clay Road Seville Apartments, Katy, TX 77449 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Innova Masonry, Inc. 4 times in Texas since 2017.
The latest one began on Oct 8, 2019 after a complaint, in Katy.
Those inspections ended with 8 citation items: 8 serious.
Penalties were first proposed at $23,360 and still stand at $23,360.
Scaffolds, general requirements comes up most often in these citations: 7 items under 1926.451.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Innova Masonry, Inc. averages $11,680 (2 cited inspections).
Texas · latest 90 days of OSHA records
401employers cited
14 of them in the same industry
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch Innova Masonry, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company20919 Clay Road Seville Apartments, Katy, TX 77449 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
28302 Highway 290, Cypress, TX 77433 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.451(b)(1) · Scaffolds, general requirements |
Serious | $3,803 | $3,803 | Mar 20, 2017 | Final |
| Citation 1, item 1b 29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements |
Serious | $0 | $0 | Mar 20, 2017 | Final |
| Citation 1, item 2 29 CFR 1926.451(c)(2) · Scaffolds, general requirements |
Serious | $2,716 | $2,716 | Mar 20, 2017 | Final |
| Citation 1, item 3 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $2,716 | $2,716 | Mar 20, 2017 | Final |
| Citation 1, item 4 29 CFR 1926.452(c)(2) · Rules for each type of scaffold |
Serious | $2,716 | $2,716 | Mar 20, 2017 | Final |
917 Southmore, Pasadena, TX 77501 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
917 Southmore, Pasadena, TX 77501 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $3,803 | $3,803 | May 25, 2017 | Final |
| Citation 1, item 2 29 CFR 1926.451(f)(3) · Scaffolds, general requirements |
Serious | $3,803 | $3,803 | May 25, 2017 | Final |
| Citation 1, item 3 29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements |
Serious | $3,803 | $3,803 | May 25, 2017 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(b)(1)
(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:
29 CFR 1926.451(c)(2)
(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.
29 CFR 1926.451(e)(1)
(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.