Integrity Medical Devices, Inc.: OSHA inspections and violations
Hammonton, New Jersey · Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers · NAICS 423450
3inspections
16citation items
$31,134current penalties
Apr 12, 2018last inspection
Integrity Medical Devices, Inc. has 3 OSHA inspections on record in New Jersey, the first in 2011.
OSHA's last visit started on Apr 12, 2018 on a referral, in Hammonton.
Across those inspections OSHA issued 16 citation items: 14 serious and 2 repeat.
OSHA proposed $53,168 in penalties. After settlements and reviews the total is $31,134, down 41%.
Most often, OSHA cited 1910.305, electrical wiring methods (5 items).
For context, across all wholesale employers the median penalty per cited inspection since 2015 is $3,424. Integrity Medical Devices, Inc. averages $13,204 over 2 cited inspections in that time.
Integrity Medical Devices, Inc. also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
New Jersey · latest 90 days of OSHA records
274employers cited
Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Integrity Medical Devices, Inc. and get notified the morning OSHA posts a new citation for it.
Incident on Apr 10, 2018: Employee amputates two fingers on machine's knife
At 9:00 a.m. on April 10, 2018, Employee #1 was trying to unjam the machine. The employee's finger got caught at the point of operation and struck against the machine's knife. Employee #1 suffered amputation of two fingers.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Hammonton site logged 1 recordable injury or illness among about 46 workers: 2.9 per 100 full-time workers, against a median of 1.1 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Integrity Medical Devices, Inc.
Hammonton · 2024
46
1
0
2.9
1.1
Included with any plan: 7 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
An employee was installing a new roll of paper in a machine when the paper became jammed. As the employee tried to pull the paper out, the machine's cross-cutter knife amputated two of the employee's fingers. The machine was unguarded and active at the time.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:
29 CFR 1910.147(f)(1)
(1) Check the machine or equipment and the immediate area around the machine or equipment to ensure that nonessential items have been removed and that the machine or equipment components are operationally intact.
(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.
29 CFR 1910.219 · Belts, pulleys and power-transmission parts
29 CFR 1910.303 · Electrical equipment, general requirements
Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.