OSHA SearchOSHA records by employer

Integrity Wall & Ceiling Inc: OSHA inspections and violations

Perrysburg, Ohio · Drywall and Insulation Contractors · NAICS 238310

9inspections
23citation items
$18,550current penalties
Mar 21, 2024last inspection

Since 1996, OSHA inspectors have visited Integrity Wall & Ceiling Inc in Ohio 9 times.

The most recent inspection opened on Mar 21, 2024 as a planned inspection, in Defiance.

In all, OSHA issued 23 citation items: 18 serious, 1 repeat and 4 other-than-serious.

The proposed penalties came to $81,852; today they stand at $18,550, 77% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 12 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Integrity Wall & Ceiling Inc averages $3,200 across 1 cited inspection.

Integrity Wall & Ceiling Inc: OSHA citation items per year, 1996 to 2024
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

267employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Integrity Wall & Ceiling Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347363376 OPENED MAR 21, 2024Closed

Planned · Complete · Safety · 12 employees at the site · Closed May 28, 2024

300 Clinton St., Defiance, OH 43512 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$6,452$3,200Apr 8, 2024Final

Inspection 311611164 OPENED SEP 15, 2009Closed

Planned · Complete · Safety · 10 employees at the site · Closed Sep 15, 2009

3139 King Rd., Sylvania, OH 43560 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311602577 OPENED MAR 24, 2008Closed

Planned · Complete · Safety · 15 employees at the site · Closed May 20, 2008

5232 Airport Hwy, Toledo, OH 43615 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$625$625Apr 4, 2008Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$375$375Apr 4, 2008Closed
Citation 1, item 3
29 CFR 1926.452(w)(2) · Rules for each type of scaffold
Serious$500$500Apr 4, 2008Closed

Inspection 309448009 OPENED JUN 7, 2007Closed

Planned · Complete · Safety · 12 employees at the site · Closed Jun 29, 2007

10017 Fremont Pike, Perrysburg, OH 43551 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$1,500Jun 12, 2007Closed

Inspection 303458616 OPENED JUN 28, 2000Closed

Complaint · Partial · Safety · 11 employees at the site · Closed Jul 19, 2002

10017 Fremont Pike, Perrysburg, OH 43551 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Other-than-serious$2,800$1,000Dec 22, 2000Final

Inspection 303458376 OPENED JUN 20, 2000Closed

Referral · Partial · Safety · 11 employees at the site · Closed Jul 16, 2002

New Fazoli's, Northwood, OH 43605 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$2,800$900Dec 1, 2000Final
Citation 1, item 4
29 CFR 1926.451(f)(14) · Scaffolds, general requirements
Serious$2,800$900Dec 1, 2000Final
Citation 2, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$28,000$3,500Dec 1, 2000Final
Citation 2, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$28,000$1,500Dec 1, 2000Final

Inspection 301533105 OPENED OCT 23, 1998Closed

Referral · Partial · Safety · 3 employees at the site · Closed Jan 20, 1999

10017 Fremont Pike, Perrysburg, OH 43551 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 301529350 OPENED JUN 27, 1997Closed

Planned · Complete · Safety · 2 employees at the site · Closed May 12, 1999

6061 Telegraph Rd., Toledo, OH 43612 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$600$700Aug 29, 1997Closed
Citation 1, item 2a
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$800$700Aug 29, 1997Closed
Citation 1, item 2b
29 CFR 1926.405(a)(2)(iii) · Job-site wiring
Serious$0$0Aug 29, 1997Closed
Citation 1, item 3a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,000$700Aug 29, 1997Closed
Citation 1, item 3b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Aug 29, 1997Closed
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$800$700Aug 29, 1997Closed
Citation 1, item 5a
29 CFR 1926.454(a) · Scaffold training
Serious$800$700Aug 29, 1997Closed
Citation 1, item 5b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Aug 29, 1997Closed
Citation 2, item 1
29 CFR 1926.451(b)(10) · Scaffolds, general requirements
Other-than-serious$0$0Aug 29, 1997Closed
Citation 2, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Other-than-serious$0$0Aug 29, 1997Closed
Citation 2, item 3
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Other-than-serious$0$0Aug 29, 1997Closed
1 older inspection

Inspection 301525713 OPENED MAY 31, 1996Closed

Unprogrammed related · Complete · Safety · 9 employees at the site · Closed Aug 27, 1997

10017 Fremont Pike, Perrysburg, OH 43551 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$525Jul 8, 1996Closed
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,500$525Jul 8, 1996Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(iii)

(iii) Guarding. For temporary wiring over 600 volts, nominal, fencing, barriers, or other effective means shall be provided to prevent access of other than authorized and qualified personnel.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

Other drywall and insulation contractors employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.