OSHA SearchOSHA records by employer

Interactive Construction Inc: OSHA inspections and violations

South Boston, Massachusetts · Residential Remodelers · NAICS 236118

2inspections
7citation items
$6,000current penalties
Jul 13, 2022last inspection

OSHA has inspected Interactive Construction Inc 2 times in Massachusetts since 2020.

The latest one began on Jul 13, 2022 after a complaint, in Westport.

Those inspections ended with 7 citation items: 6 serious and 1 other-than-serious.

Penalties were first proposed at $22,300 and now stand at $6,000, 73% lower after settlements or reviews.

Excavations comes up most often in these citations: 2 items under 1926.651.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,078, and Interactive Construction Inc averages $6,000 (1 cited inspection).

Interactive Construction Inc: OSHA citation items per year, 2020 to 2022
Citation items per year, by inspection date.

Want to know if OSHA cites Interactive Construction Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346076524 OPENED JUL 13, 2022Closed

Complaint · No inspection · Safety · 1 employee at the site · Closed Oct 3, 2022

1612 B Drift Road, Westport, MA 02790 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344609052 OPENED FEB 5, 2020Closed

Referral · Partial · Safety · 5 employees at the site · Closed Jun 2, 2022

383 K Street, South Boston, MA 02127 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.21(b)(2) · Construction safety training
Serious$4,048$2,000Apr 28, 2020Final
Citation 1, item 1b
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,048$0Apr 28, 2020Final
Citation 1, item 2
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$1,735$1,735Apr 28, 2020Final
Citation 1, item 4a
29 CFR 1926.651(a) · Excavations
Serious$4,048$2,000Apr 28, 2020Final
Citation 1, item 4b
29 CFR 1926.651(b)(1) · Excavations
Serious$4,048$0Apr 28, 2020Final
Citation 1, item 4c
29 CFR 1926.652(a)(1) · Trench protection
Serious$4,048$0Apr 28, 2020Final
Citation 2, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$325$265Apr 28, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(2)

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

Other residential remodelers employers in Massachusetts

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.