OSHA SearchOSHA records by employer

International Line Builders, Inc.: OSHA inspections and violations

Montecito, California · Power and Communication Line and Related Structures Construction · NAICS 237130

24inspections
11citation items
$16,950current penalties
Nov 6, 2025last inspection

Since 1990, OSHA inspectors have visited International Line Builders, Inc. in California 24 times.

The most recent inspection opened on Nov 6, 2025 after an accident, in Irvine.

In all, OSHA issued 11 citation items: 1 serious and 10 other-than-serious.

The proposed penalties came to $56,985; today they stand at $16,950, 70% less.

The rule cited most here is 2320.2 (), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. International Line Builders, Inc. averages $1,012 across 4 cited inspections.

2 inspections on this page followed a fatal incident.

International Line Builders, Inc.: OSHA citation items per year, 1990 to 2025
Citation items per year, by inspection date.

California · latest 90 days of OSHA records

1,139employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in California: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in California

Checking a subcontractor, a client or your own company? Watch International Line Builders, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348583675 OPENED NOV 6, 2025Closed

Accident · Partial · Safety · 264 employees at the site · Closed Jan 21, 2026

8261 Marine Way, Irvine, CA 92618 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 341.1(H)(2)(B)
Other-than-serious$300$300Dec 15, 2025Final

Inspection 345281844 OPENED APR 28, 2021Closed

Referral · Partial · Safety · 100 employees at the site · Closed Sep 7, 2021

Firland Drive, Paradise, CA 95969 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 3395(I)
Other-than-serious$185$0Apr 30, 2021Final

Inspection 344841499 OPENED JUL 20, 2020Open

Accident · Partial · Safety · 160 employees at the site · Open

3 Miles N. Of Eagle Lakes Road Exit Off I-80 Fwy., Soda Springs, CA 95728 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jul 13, 2020: Two employees sustain blunt trauma in fall from power poles

At 9:30 a.m. on July 13, 2020, Employee #1 and Employee #2 were working as electrical power transmission line workers for an electrical company. The employees were part of a field crew working along with three other coworkers at a remote site. The crew was tasked with installing insulators on existing 48-foot power transmission poles (H-Structures) for a utility company. Employee #1 and Employee #2 climbed up their respective wooden power poles and were approximately 40 feet above the ground. Due to the local terrain, the existing power poles were not driven and anchored into the granite outcropping. Employee #1 began the process of installing insulators on one pole while Employee #2 removed the support lines to his pole. Both wooden power poles began to lean and tip over as both employees hung onto the poles as they fell. Employee #1 fractured his leg and received medical treatment without hospitalization. Employee #2 fractured his pelvis and several back vertebrae and damaged his knee and face. Employee #2 was airlifted from the site while Employee #1 was transported via ground to a medical center. Employee #1 was treated and released the same day while Employee #2 was hospitalized and released after 4 days.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 342(A)
Other-than-serious$5,000$3,750Jan 7, 2021Final

Inspection 342782372 OPENED NOV 13, 2017Closed

Accident · Partial · Safety · 433 employees at the site · Closed Aug 3, 2020

1255 Via Del Ray, South Pasadena, CA 91030 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Aug 30, 2017: Worker removing trench box incurs finger amputation

At 2:50 p.m. on August 30, 2017, Employee #1 and Coworker #1, employed by a company that provided electrical construction services, were part of a crew assigned to install a 7 feet by 14 feet by 8 feet vault in an excavation. They used a double stacked trench box to provide cave-in protection during the installation. After setting the vault, they began to remove the trench box. Employee #1 and Coworker #1 were working in the trench box, kneeling on top of the vault and removing nuts and bolts, when Employee #1's right hand became caught between a nut and the bottom shield of the trench box. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for the amputation of his index finger.

No citations from this inspection.

Inspection 342536091 OPENED AUG 9, 2017Closed

Unprogrammed related · Partial · Safety · 4 employees at the site · Closed Jan 18, 2018

150 Sondra Way, Campbell, CA 95008 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341267698 OPENED FEB 22, 2016Closed

Complaint · Partial · Safety · 230 employees at the site · Closed Mar 8, 2017

16th & 3rd Street, Upland, CA 91784 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$300$0Jul 22, 2016Final

Inspection 340869635 OPENED AUG 19, 2015Closed

Complaint · Partial · Safety · 1 employee at the site · Closed Dec 21, 2015

Valley Blvd, East Of Garvey, El Monte, CA 91732 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 126160753 OPENED SEP 4, 2014Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Apr 5, 2018

1156 Hugo Reid Dr., Arcadia, CA 91007 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

16 older inspections

Inspection 314862707 OPENED JUL 19, 2012Closed

Accident · Partial · Safety · 300 employees at the site · Closed Oct 2, 2012

Lmu Campus Ignatian Cir., Los Angeles, CA 90045 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

Incident on Jul 18, 2012: Employee is burned when excavator hits water line

At 1:00 p.m. on July 18, 2012, Employee #1, of International Line Builders, Inc. , was working at an excavation site at Loyola Marymount University, part of a pr oject to rebuild the hot water line. The employer, a subcontractor, was hired to dig up new line on the road. The new line was 3 feet wide by 2 feet deep. Cowor ker #1, while operating excavator equipment, hit an unmarked underground hot wat er line. The hot water line burst open, and hot water began to fill the excavati on. According to Employee #1, he was instructed by coworker #2, his foreman, to open the manhole beside the 6 foot to 8 foot deep excavation. Employee #1 used a hook to pry up the manhole cover. The hook dislodged from the cover, causing Em ployee #1 to lose balance. Employee #1 stepped backwards and fell into the trenc h. At that point the excavation was about half full of hot water. While falling, Employee #1 was able to catch himself and push himself out of the trench, but n ot before experiencing serious burns to both legs, stomach, and hands from hot w ater splashes. Employee #1 took off his clothes and work boots, and he was hosed down with cold water. He was taken by paramedics to Marino Hospital and then tr ansferred to West Hills Burn Center. According to coworker #2, the foreman, the excavation at the time of accident was 2 feet wide by 4 feet long by 30 inches d eep. Field investigation verified these measurements.

No citations from this inspection.

Inspection 315526434 OPENED OCT 27, 2011Closed

Accident · Partial · Safety · 120 employees at the site · Closed Mar 8, 2012

2540 W. Lincoln Ave, Anaheim, CA 92804 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Oct 26, 2011: Employee is burned in transformer explosion

On October 26, 2011, Employee #1 was the foreman of a four-person crew working f or a company that built and maintained electric power distribution systems. The crew was replacing an existing unfused 225 KVA pad mount transformer (PMT) with a new fused 300 KVA PMT. The existing overhead feed was to be replaced with a ne w underground feed for the new transformer. After crew members isolated the exis ting PMT from the overhead service, they realized that they neglected to identif y the phase sequence. A rotation meter was to be used to identify the phase sequ ence, which required them to reconnect the overhead service. Temporary jumpers w ere used to reconnect the power from the overhead lines to the pothead feeding t he PMT. Employee #1 was located directly in front of the PMT with an 8-ft hot st ick attached to the PMT switch to reenergize its secondary side. A coworker was standing on the back side of the PMT, holding the rotation meter that was connec ted with long leads to the front of the PMT. When Employee #1 turned on the PMT switch with the hot stick, there was no reading on the rotation meter. Employee #1 turned off the PMT switch and asked the coworker to hold down the button on t he meter to enable the reading. When Employee #1 again turned the on the PMT swi tch with the hot stick, the PMT exploded. Hot oil spewed out and ignited. Employ ee #1 was hospitalized with first- and second-degree burns to his face, hands, a nd upper back. The coworker sustained minor burns to his face.

No citations from this inspection.

Inspection 314793365 OPENED DEC 13, 2010Closed

Accident · Partial · Safety · 3 employees at the site · Closed Aug 22, 2012

Vista Park Drive And Branham Lane, San Jose, CA 95111 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313166340 OPENED JUL 19, 2010Closed

Planned · Partial · Safety · 100 employees at the site · Closed Aug 4, 2010

Santa Ana Blvd & Harbor Blvd, Anaheim, CA 92805 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 125714832 OPENED JAN 20, 2006Closed

Accident · Partial · Safety · 4 employees at the site · Closed Sep 9, 2008

6052 40th Ave, Sacramento, CA 95824 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Jan 12, 2006: Employee injured when struck by falling crane boom

On January 12, 2006, Employee #1 was stowing an extended jib on a Manitex crane. He had removed two pins from the right side of the unit, lined up the holes of the jib, and then taken out the top pin. Employee #1 was removing the bottom pin when the jib fell on him, striking him in the face and sliding down onto his ch est. Employee #1 sustained injuries that required hospitalization.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 342 A
Other-than-serious$5,000$4,500May 9, 2006Final
Citation 2, item 1
29 CFR 3203 A07 C
Other-than-serious$8,440$2,500May 9, 2006Final

Inspection 300895240 OPENED MAR 30, 2004Closed

Accident · Partial · Safety · 10 employees at the site · Closed Mar 16, 2007

649 Green Street, San Francisco, CA 94133 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Mar 11, 2004: Employee burned during installation of power line

At approximately 8:00 a.m. on March 10, 2004, Employee #1, a journeyman lineman, was in the bucket of an aerial truck, installing a PG & E pole and overhead pow er line in San Francisco, CA. He was holding an energized secondary conductor an d getting ready to connect it when he removed the leather glove on his right han d to reach for his skinning knife. As he moved, the conductor contacted another energized part and created an electrical flare. Employee #1 sustained burns to h is right hand, face, and part of his left thigh. The foreman transported him to St. Francis Hospital, where he was admitted for treatment of second-degree burns . Subsequent investigation revealed different accounts of the events from Employ ee #1's foreman, who was approximately 15 ft away from the pole, and a coworker, who was slightly below Employee #1 on the other side of the pole. The employer was cited for an accident-related violation of T8CCR 2320.2(a)(3)(A), serious, b ecause Employee #1 was not wearing rubber insulating gloves that met standrad sp ecifications. The leather gloves he was using were not approved for work on ener gized equipment. Employee #1 later returned to light-duty work.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$360$0Aug 27, 2004Final
Citation 2, item 1 Other-than-serious$16,200$600Aug 27, 2004Final

Inspection 125716886 OPENED DEC 10, 2003Closed

Accident · Partial · Safety · 12 employees at the site · Closed Aug 25, 2004

8210 Berry Ave. #180, Sacramento, CA 95828 · All Other Miscellaneous Electrical Equipment and Component Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Nov 18, 2003: Employee fractures leg in fall from electric pole

On November 18, 2003 an employee was working from a power pole at a height of 42 feet when he fell. The employee was wearing a climbing belt and removed it to p erform a point-to-point operation to get around a cross bar. A coworker was on t he ground at the time of the accident and called emergency medical services. The Sacramento City Fire Department arrived at the scene and provided first aid to the employee. The employee was transported to U.C. Davis Medical Center, where h e was hospitalized and treated for multiple fractures to his leg.

No citations from this inspection.

Inspection 301138236 OPENED OCT 14, 2003Closed

Accident · Partial · Safety · 251 employees at the site · Closed Nov 14, 2003

827 Indian Rock Avenue, Berkeley, CA 94707 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 300816584 OPENED SEP 9, 2003Closed

Accident · Partial · Safety · 70 employees at the site · Closed Oct 16, 2006

Dinosaur Point Road, Los Banos, CA 93635 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Incident on Sep 8, 2003 (fatal): Employee electrocuted during change of utility poles

Employee #1, a journeyman lineman for Pacific Gas and Electric, was part of a fi ve-person crew changing out utility poles in Los Banos, CA. The crew had set new anchor rods, tested the lines to ensure they were deenergized, and grounded the m to earth in two directions with ground rods. They changed the poles, transferr ed the power lines, and were finishing the jumper on the last pole by connecting the guys and removing the old poles. Employee #1 put a chain ratchet on the "T" of a ground rod, then walked over to the pole where the east guy had already be en temporarily pulled. He picked up the west guy below the grip and walked back to the ratchet that was lying on the ground rod. When Employee #1 grabbed the ra tchet, he was electrocuted.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 2941 H11
Serious$16,200$5,000Mar 4, 2004Final

Inspection 125629402 OPENED NOV 27, 2000Closed

Unprogrammed related · Partial · Safety · 4 employees at the site · Closed Jun 25, 2002

19131 Crest Avenue, Castro Valley, CA 94546 · OSHA's record · Phone and website on Google Maps

Incident on Nov 27, 2000 (fatal): Electric shock - direct contact with overhead line

A power line worker was working from an aerial lift. He was working on a deenerg ized transformer. The operating controls for the aerial lift became entangled in a loop of secondary lead conductor, which caused the bucket on the aerial lift to ascend. This crushed and buckled the fiberglass bucket against the transforme r. When the bucket was moved away from the transformer, it sprang back into shap e, catapulting the employee into a 6950-volt overhead power line. The employee w as electrocuted.

No citations from this inspection.

Inspection 126139062 OPENED JUN 28, 1999Closed

Follow-up · Partial · Safety · 70 employees at the site · Closed Aug 18, 1999

600 Toro Canyon Road, Montecito, CA 93117 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 126141910 OPENED APR 2, 1999Closed

Follow-up · Complete · Safety · 65 employees at the site · Closed Apr 2, 1999

2500 East Valley Rd, Motecito, CA 93117 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 126211028 OPENED JUL 21, 1997Closed

Accident · Complete · Safety · 105 employees at the site · Closed May 7, 1998

600 Toro Canyon Road, Montecito, CA 93117 · OSHA's record · Phone and website on Google Maps

Incident on Jul 18, 1997: Employee's foot amputated when caught by outrigger

At approximately 12:30 p.m. on July 18, 1997, Employee #1, of International Line Builders, was asked to move a bucket truck. The truck's engine was running, and its bucket and boom had been moved to the 'down' position by the bucket operato r. Employee #1 walked from the cab to the right rear control panel to lift the o utriggers/stabilizers to the 'home' position before he moved the truck. When he lifted the outriggers, the truck began to roll backward. Employee #1's left ankl e became caught between the edge of the outrigger foot and a cement pad, amputat ing his foot. Employee #1 later stated that he had left the cab with the truck's emergency brake set. His coworker, who was resting in the cab, with his eyes cl osed, said he didn't know if the brake was set or not, but that he didn't releas e the brake. Tests showed that the truck's brakes were working fine before and a fter the accident.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 3203 B02
Other-than-serious$1,500$300Oct 24, 1997Final

Inspection 119989077 OPENED MAY 12, 1993Closed

Accident · Partial · Safety · 4 employees at the site · Closed May 12, 1993

9525 Bray Avenue, Spring Valley, CA 91977 · OSHA's record · Phone and website on Google Maps

Incident on May 5, 1993: Fall - gaff cutout

An apprentice power line worker was climbing a utility pole. As he was climbing he fell 20 to 25 feet to the ground. (The employee stated that he thought he mig ht have put his right gaff into a crack in the pole. However, a post-accident in spection of the pole did not reveal any defects. The employee's gaff apparently cut out from the pole.) He struck the ground, landing on his back, shoulder firs t. The fall left him breathless. By the time other crew members came to his aid and called for emergency medical assistance, he had risen. Emergency medical ser vices arrived within about 5 minutes, and the injured employee was transported t o a hospital. He was hospitalized for a fractured left forearm near the wrist an d for shoulder and back muscle strain.

No citations from this inspection.

Inspection 111868592 OPENED APR 27, 1992Closed

Accident · Partial · Safety · 10 employees at the site · Closed Jun 15, 1993

2879 Curie Place, San Diego, CA 92122 · OSHA's record · Phone and website on Google Maps

Incident on Apr 17, 1992: Electric shock - contact with overhead line thru hoist

A CONTRACTOR FOR AN ELECTRIC UTILITY WAS REPLACING LINES ON A 69-KILOVOLT CIRCUI T. A POWER LINE WORKER ON THE CREW HAD JUST DEAD-ENDED ONE PHASE OF THE DEENERGI ZED 69-KILOVOLT LINE. HE WAS BELTED OFF TO A UTILITY POLE, WITH HIS CLIMBERS IN THE POLE BELOW THE LINE. HE WAS HOLDING A HOIST WITH BOTH HANDS AND HAD HIS RIGH T LEG IN CONTACT WITH AN UNINSULATED GUY. AS HE WAS TRANSFERRING THE LINE TENSIO NING HOIST TO ANOTHER CONDUCTOR, THE GRIP ON THE END OF THE HOIST CONTACTED A PA RTIALLY PROTECTED 12-KILOVOLT LINE BELOW HIM. THE POWER LINE WORKER WAS KNOCKED UNCONSCIOUS BY THE ELECTRIC SHOCK HE RECEIVED, AND HE HUNG UPSIDE DOWN FROM HIS BELT. A COWORKER ON THE SAME POLE CAME TO HIS RESCUE FROM THE OTHER SIDE OF THE CROSSARM ON THE POLE. THE RESCUER ATTACHED A HAND LINE TO HIS INJURED PARTNER, W HO REGAINED CONSCIOUSNESS. WITH THE ASSISTANCE OF THREE GROUND WORKERS, THE COWO RKER LOWERED HIM TO THE GROUND. THE FOREMAN, WHO HAD BEEN OBSERVING THE OPERATIO N FROM THE GROUND, CALLED THE DISPATCHER TO REQUEST EMERGENCY MEDICAL SERVICES. THE INJURED LINE WORKER WAS ABLE TO WALK TO A BANK TO WAIT FOR THE AMBULANCE. TH E AMBULANCE TRANSPORTED THE EMPLOYEE TO A BURN UNIT, WHERE HE WAS HOSPITALIZED W ITH SEVERE BURNS TO BOTH HANDS AND TO HIS RIGHT LEG. HIS LEFT THUMB HAD TO BE AM PUTATED WITH TWO OF ITS JOINTS, AND SKIN GRAFTS WERE APPLIED TO HEAL THE 6-INCH DIAMETER BURN ON HIS RIGHT LEG.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$3,500$0Sep 17, 1992Final

Inspection 112004536 OPENED DEC 26, 1990Closed

Accident · Complete · Safety · 9 employees at the site · Closed Jul 31, 1991

Valley Parkway & I-15, Escondido, CA 92025 · OSHA's record · Phone and website on Google Maps

Incident on Dec 20, 1990: Electric shock - direct contact with overhead line

A power line worker was on a utility pole, working on a deenergized overhead pow er line. He contacted a nearby, energized 12-kilovolt power line that had not be en covered with insulating equipment. The employee, who was standing on a brace that was in contact with an unprotected guy, received an electric shock. Coworke rs in an aerial lift rescued him as he hung from his body belt, which was attach ed to the crossarm on the pole. A supervisor summoned emergency medical services , and they arrived in about 10 minutes. The injured employee was hospitalized at a burn center. He was treated for burns to his right hand and both feet. Doctor s later amputated his right index finger.

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 2320.2

29 CFR 2940.6

29 CFR 4300.29

Other power and communication line and related structures construction employers in California

Alert subscribers get notified of each newly cited employer in California the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.