Inspection 342466778 OPENED JUL 6, 2017Closed
6130 Lago Mar Blvd Catalon At Lago Mar Apts, Texas City, TX 77592 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Texas City, Texas · Framing Contractors · NAICS 238130
Since 2016, OSHA inspectors have visited Irad Barrios in Texas 3 times.
The most recent inspection opened on Jul 6, 2017 to follow up on an earlier case, in Texas City.
In all, OSHA issued 8 citation items: 8 serious.
The proposed penalties came to $9,768; today they stand at $5,368, 45% less.
The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Irad Barrios averages $2,684 across 2 cited inspections.
Texas · latest 90 days of OSHA records
398employers cited
59 of them in the same industry
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch Irad Barrios and get notified the morning OSHA posts a new citation for it.
Watch this company6130 Lago Mar Blvd Catalon At Lago Mar Apts, Texas City, TX 77592 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
6130 Lago Mar Blvd Catalon At Lago Mar Apts, Texas City, TX 77592 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.451(f)(7) · Scaffolds, general requirements |
Serious | $2,390 | $1,434 | Mar 23, 2017 | Final |
| Citation 1, item 1b 29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements |
Serious | $0 | $0 | Mar 23, 2017 | Final |
| Citation 1, item 1c 29 CFR 1926.451(c)(2) · Scaffolds, general requirements |
Serious | $0 | $0 | Mar 23, 2017 | Final |
| Citation 1, item 1d 29 CFR 1926.451(g)(3)(iv) · Scaffolds, general requirements |
Serious | $0 | $0 | Mar 23, 2017 | Final |
| Citation 1, item 1e 29 CFR 1926.452(j)(2) · Rules for each type of scaffold |
Serious | $0 | $0 | Mar 23, 2017 | Final |
| Citation 1, item 2 29 CFR 1926.454(b) · Scaffold training |
Serious | $2,390 | $1,434 | Mar 23, 2017 | Final |
2969 Main Street, Ingleside, TX 78362 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.21(b)(2) · Construction safety training |
Serious | $4,988 | $2,500 | Sep 12, 2016 | Final |
| Citation 1, item 1b 29 CFR 1926.453(b)(2)(v) · Aerial lifts |
Serious | $0 | $0 | Sep 12, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.21(b)(2)
(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.
29 CFR 1926.451(b)(5)(ii)
(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.
29 CFR 1926.451(c)(2)
(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.