OSHA SearchOSHA records by employer

Isd 16 - Westwood Intermediate and Middle School: OSHA inspections and violations

Minneapolis, Minnesota · Elementary and Secondary Schools · NAICS 611110

1inspections
6citation items
$7,560current penalties
Mar 27, 2024last inspection

OSHA has inspected Isd 16 - Westwood Intermediate and Middle School once in Minnesota.

The inspection began on Mar 27, 2024 as a planned inspection, in Minneapolis.

That inspection ended with 6 citation items: 5 serious and 1 other-than-serious.

Penalties were first proposed at $18,900 and now stand at $7,560, 60% lower after settlements or reviews.

Permit-required confined spaces comes up most often in these citations: 3 items under 1910.146.

How that compares: the median penalty per cited inspection for education employers since 2015 is $0, and Isd 16 - Westwood Intermediate and Middle School averages $7,560 (1 cited inspection).

Isd 16 - Westwood Intermediate and Middle School: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

364employers cited

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Isd 16 - Westwood Intermediate and Middle School and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347381477 OPENED MAR 27, 2024Closed

Planned · Complete · Safety · Local government · 163 employees at the site · Closed Mar 14, 2025

711 91st Avenue Ne, Minneapolis, MN 55434 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$2,100$840May 2, 2024Final
Citation 1, item 3
29 CFR 1910.146(c)(4) · Permit-required confined spaces
Serious$4,200$1,680May 2, 2024Final
Citation 1, item 4
29 CFR 1910.146(g)(2) · Permit-required confined spaces
Serious$4,200$1,680May 2, 2024Final
Citation 1, item 5
29 CFR 1910.146(k)(1) · Permit-required confined spaces
Serious$4,200$1,680May 2, 2024Final
Citation 1, item 6
29 CFR 1910.212(a)(1) · Machine guarding
Serious$3,500$1,400May 2, 2024Final
Citation 2, item 2 Other-than-serious$700$280May 2, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(a)(2)

(2) The CNP system defaults selected for test pressure shall be set at −15 mm of water (-0.58 inches of water) and the modeled inspiratory flow rate shall be 53.8 liters per minute for performing fit tests.

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.146(c)(4)

(4) If the employer decides that its employees will enter permit spaces, the employer shall develop and implement a written permit space program that complies with this section. The written program shall be available for inspection by employees and their authorized representatives.

29 CFR 1910.146(g)(2)

(2) Training shall be provided to each affected employee:

29 CFR 1910.212 · Machine guarding

29 CFR 5205.1200

Other elementary and secondary schools employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.