OSHA SearchOSHA records by employer

Isd 720 - East Junior High School: OSHA inspections and violations

Shakopee, Minnesota · Elementary and Secondary Schools · NAICS 611110

1inspections
6citation items
$1,125current penalties
Mar 19, 2019last inspection

OSHA has inspected Isd 720 - East Junior High School once in Minnesota.

The inspection began on Mar 19, 2019 as a planned inspection, in Shakopee.

That inspection ended with 6 citation items: 4 serious and 2 other-than-serious.

Penalties were first proposed at $7,000 and now stand at $1,125, 84% lower after settlements or reviews.

Woodworking machinery comes up most often in these citations: 3 items under 1910.213.

How that compares: the median penalty per cited inspection for education employers since 2015 is $0, and Isd 720 - East Junior High School averages $1,125 (1 cited inspection).

Isd 720 - East Junior High School: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

371employers cited

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Isd 720 - East Junior High School and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343883666 OPENED MAR 19, 2019Closed

Planned · Complete · Safety · Local government · 118 employees at the site · Closed Sep 2, 2020

1137 Marschall Road S., Shakopee, MN 55379 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$1,750$281Apr 10, 2019Final
Citation 1, item 2
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$1,050$169Apr 10, 2019Final
Citation 1, item 3
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$1,750$281Apr 10, 2019Final
Citation 1, item 4
29 CFR 1910.1030(g)(2)(ii)(b) · Bloodborne pathogens
Serious$1,750$281Apr 10, 2019Final
Citation 2, item 1
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$350$56Apr 10, 2019Final
Citation 2, item 2 Other-than-serious$350$56Apr 10, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1030 · Bloodborne pathogens

29 CFR 1910.1030(g)(2)(ii)(b)

(B) At least annually thereafter.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1910.213(c)(2)

(2) Each hand-fed circular ripsaw shall be furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator. The spreader shall be made of hard tempered steel, or its equivalent, and shall be thinner than the saw kerf. It shall be of sufficient width to provide adequate stiffness or rigidity to resist any reasonable side thrust or blow tending to bend or throw it out of position. The spreader shall be attached so that it will remain in true alignment with the saw even when either the saw or table is tilted. The provision of a spreader in connection with grooving, dadoing, or rabbeting is not required. On the completion of such operations, the spreader shall be immediately replaced.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 5206.700

Other elementary and secondary schools employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.