OSHA SearchOSHA records by employer

Ismael Villegas: OSHA inspections and violations

Mount Juliet, Tennessee · Masonry Contractors · NAICS 238140

1inspections
7citation items
$6,450current penalties
Mar 26, 2018last inspection

OSHA has inspected Ismael Villegas once in Tennessee.

The inspection began on Mar 26, 2018 as a planned inspection, in Mount Juliet.

That inspection ended with 7 citation items: 7 serious.

Penalties were first proposed at $6,450 and still stand at $6,450.

Scaffolds, general requirements comes up most often in these citations: 6 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Ismael Villegas averages $6,450 (1 cited inspection).

Ismael Villegas: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

342employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Ismael Villegas and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343040697 OPENED MAR 26, 2018Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jun 7, 2018

1984 Providence Parkway, Mount Juliet, TN 37122 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,050$1,050Apr 27, 2018Final
Citation 1, item 2
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$1,050$1,050Apr 27, 2018Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,050$1,050Apr 27, 2018Final
Citation 1, item 4a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,050$1,050Apr 27, 2018Final
Citation 1, item 4b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Apr 27, 2018Final
Citation 1, item 5
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,200$1,200Apr 27, 2018Final
Citation 1, item 6
29 CFR 1926.454(a) · Scaffold training
Serious$1,050$1,050Apr 27, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)(ii)

(ii) Unstable objects shall not be used to support scaffolds or platform units.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.