J & J Erectors: OSHA inspections and violations

Houston, Texas · Structural Steel and Precast Concrete Contractors · NAICS 238120

4inspections
12citation items
$10,878current penalties
Feb 23, 2017last inspection

J & J Erectors has 4 OSHA inspections on record in Texas, the first in 2003.

OSHA's last visit started on Feb 23, 2017 as a planned inspection, in Houston.

Across those inspections OSHA issued 12 citation items: 10 serious and 2 repeat.

OSHA proposed $21,514 in penalties. After settlements and reviews the total is $10,878, down 49%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. J & J Erectors averages $3,916 over 2 cited inspections in that time.

J & J Erectors: OSHA citation items per year, 2003 to 2017
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch J & J Erectors and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342128568 OPENED FEB 23, 2017Closed

Planned · Partial · Health · 8 employees at the site · Closed Sep 14, 2017

2697 Fm 1960 Rd, Houston, TX 77073 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$5,432$2,716Aug 14, 2017Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Repeat$5,432$2,716Aug 14, 2017Final

Inspection 340773092 OPENED JUL 13, 2015Closed

Planned · Complete · Safety · 5 employees at the site · Closed Aug 13, 2015

1630 Loop 1604, San Antonio, TX 78251 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,600$800Jul 27, 2015Final
Citation 1, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$1,600$800Jul 27, 2015Final
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,600$800Jul 27, 2015Final

Inspection 308318468 OPENED JAN 12, 2006Closed

Planned · Partial · Health · 4 employees at the site · Closed Sep 14, 2006

Corner Of Kirkville & Blackhawk, Houston, TX 77089 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.350(a)(9) · Gas welding and cutting
Serious$1,500$750Feb 2, 2006Closed
Citation 1, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,050$526Feb 2, 2006Closed
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,050$525Feb 2, 2006Closed
Citation 1, item 4a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,050$525Feb 2, 2006Closed
Citation 1, item 4b
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Feb 2, 2006Closed

Inspection 306066739 OPENED DEC 10, 2003Closed

Unprogrammed related · Partial · Safety · 3 employees at the site · Closed Apr 29, 2004

5168 Ne I 10 Frontage Road, Sealy, TX 77473 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.760(b)(3) · Fall protection
Serious$600$360Feb 19, 2004Closed
Citation 1, item 2
29 CFR 1926.1053(b)(10) · Ladders in construction
Serious$600$360Feb 19, 2004Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(10)

(10) The top of a non-self-supporting ladder shall be placed with the two rails supported equally unless it is equipped with a single support attachment.

29 CFR 1926.350 · Gas welding and cutting

29 CFR 1926.350(a)(9)

(9) Compressed gas cylinders shall be secured in an upright position at all times except, if necessary, for short periods of time while cylinders are actually being hoisted or carried.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.760 · Fall protection

Other structural steel and precast concrete contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.