OSHA SearchOSHA records by employer

J&L Companies, Inc: OSHA inspections and violations

Newark, New Jersey · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

3inspections
3citation items
$7,170current penalties
Jul 24, 2017last inspection

J&L Companies, Inc has 3 OSHA inspections on record in New Jersey, the first in 2017.

OSHA's last visit started on Jul 24, 2017 after a complaint, in Newark.

Across those inspections OSHA issued 3 citation items: 3 serious.

OSHA proposed $11,153 in penalties. After settlements and reviews the total is $7,170, down 36%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. J&L Companies, Inc averages $3,585 over 2 cited inspections in that time.

J&L Companies, Inc: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

270employers cited

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch J&L Companies, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342492501 OPENED JUL 24, 2017Closed

Complaint · Partial · Safety · 15 employees at the site · Closed Aug 18, 2017

95-111 Rail Road Ave, Newark, NJ 07105 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342360427 OPENED MAY 19, 2017Closed

Complaint · Partial · Safety · 15 employees at the site · Closed Nov 9, 2017

95-111 Railroad Ave, Newark, NJ 07105 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(iv) · Scaffolds, general requirements
Serious$3,186$2,390Aug 8, 2017Final

Inspection 342060571 OPENED JAN 6, 2017Closed

Complaint · Partial · Safety · 15 employees at the site · Closed Aug 30, 2017

95-111 Rail Road Ave, Newark, NJ 07105 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$5,070$2,390Apr 13, 2017Final
Citation 1, item 2
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$2,897$2,390Apr 13, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(4)(iv)

(iv) When midrails are used, they shall be installed at a height approximately midway between the top edge of the guardrail system and the platform surface.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

Other new multifamily housing construction (except for-sale builders) employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.