OSHA SearchOSHA records by employer

J Century Construction Inc.: OSHA inspections and violations

Downers Grove, Illinois · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

1inspections
4citation items
$5,200current penalties
Aug 10, 2023last inspection

OSHA has inspected J Century Construction Inc. once in Illinois.

The inspection began on Aug 10, 2023 as a planned inspection, in Downers Grove; the case is still open.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $10,047 and now stand at $5,200, 48% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and J Century Construction Inc. averages $5,200 (1 cited inspection).

J Century Construction Inc.: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

426employers cited

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch J Century Construction Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346899834 OPENED AUG 10, 2023Open

Planned · Partial · Safety · 2 employees at the site · Open

3859 Douglas, Downers Grove, IL 60515 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,349$1,700Sep 14, 2023Final
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Sep 14, 2023Final
Citation 1, item 2
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$3,349$1,800Sep 14, 2023Final
Citation 1, item 3
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$3,349$1,700Sep 14, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(1)(ii)

(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

Other new single-family housing construction (except for-sale builders) employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.