OSHA SearchOSHA records by employer

J D Roth and Company: OSHA inspections and violations

Houston, Texas · Framing Contractors · NAICS 238130

7inspections
15citation items
$22,109current penalties
Feb 7, 2017last inspection

Since 2000, OSHA inspectors have visited J D Roth and Company in Texas 7 times.

The most recent inspection opened on Feb 7, 2017 as a planned inspection, in Houston.

In all, OSHA issued 15 citation items: 13 serious, 1 repeat and 1 other-than-serious.

The proposed penalties came to $24,282; today they stand at $22,109, 9% less.

The rule cited most here is 1926.501 (fall protection in construction), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. J D Roth and Company averages $3,259 across 1 cited inspection.

J D Roth and Company: OSHA citation items per year, 2000 to 2017
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

58 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch J D Roth and Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342087905 OPENED FEB 7, 2017Closed

Planned · Partial · Safety · 5 employees at the site · Closed Mar 31, 2017

9351 Fm 1960 W, Houston, TX 77049 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$2,716$1,630Mar 13, 2017Final
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,716$1,630Mar 13, 2017Final

Inspection 314897976 OPENED OCT 8, 2010Closed

Planned · Complete · Safety · 7 employees at the site · Closed Feb 21, 2013

185 West Road, Houston, TX 77037 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$3,000$3,000Oct 21, 2010Closed
Citation 1, item 2
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Repeat$6,000$6,000Oct 21, 2010Closed

Inspection 311965396 OPENED AUG 15, 2009Closed

Planned · Partial · Safety · 5 employees at the site · Closed Oct 5, 2010

5223 Broadway, Galveston, TX 77551 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$1,400$1,400Sep 4, 2009Closed
Citation 1, item 2
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Serious$1,400$1,400Sep 4, 2009Closed

Inspection 312247174 OPENED JUN 13, 2008Closed

Planned · Complete · Safety · 6 employees at the site · Closed Dec 17, 2008

Hwy 242 & Honor Roll Ln, Conroe, TX 77384 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$300$300Jul 11, 2008Closed
Citation 1, item 2
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$300$300Jul 11, 2008Closed

Inspection 308593581 OPENED JUL 24, 2006Closed

Unprogrammed other · Complete · Safety · 6 employees at the site · Closed May 2, 2008

185 West Road, Houston, TX 77037 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,500$1,500Sep 22, 2006Closed
Citation 1, item 2
29 CFR 1926.503(c) · Fall protection training in construction
Serious$1,500$1,500Sep 22, 2006Closed
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,500$1,500Sep 22, 2006Closed

Inspection 304510506 OPENED OCT 30, 2002Closed

Unprogrammed other · Complete · Safety · 6 employees at the site · Closed Jan 23, 2003

185 West Road, Houston, TX 77037 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(g)(1)(iiic) · Job-site wiring
Other-than-serious$0$0Nov 26, 2002Closed

Inspection 123626848 OPENED MAY 11, 2000Closed

Unprogrammed other · Partial · Health · 3 employees at the site · Closed Feb 26, 2002

10415 Bissonet, Houston, TX 77099 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$1,500Sep 15, 2000Closed
Citation 1, item 1b
29 CFR 1926.503(c) · Fall protection training in construction
Serious$0$0Sep 15, 2000Closed
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$450$450Sep 15, 2000Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(1)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other framing contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.