J.J. Stucco: OSHA inspections and violations

Greenwood, Indiana · Other Foundation, Structure, and Building Exterior Contractors · NAICS 238190

1inspections
7citation items
$9,600current penalties
Oct 3, 2024last inspection

OSHA inspectors have visited J.J. Stucco in Indiana one time.

It opened on Oct 3, 2024 after a complaint, in Greenwood and is still open.

In all, OSHA issued 7 citation items: 7 serious.

The penalties, $9,600 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 6 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. J.J. Stucco averages $9,600 across 1 cited inspection.

J.J. Stucco: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

79employers cited

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch J.J. Stucco and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347793176 OPENED OCT 3, 2024Open

Complaint · Partial · Safety · 6 employees at the site · Open

1230 Us Hwy 31 North, Greenwood, IN 46142 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$1,200$1,200Mar 20, 2025Final
Citation 1, item 2
29 CFR 1926.451(b)(10) · Scaffolds, general requirements
Serious$1,400$1,400Mar 20, 2025Final
Citation 1, item 3
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$1,400$1,400Mar 20, 2025Final
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,400$1,400Mar 20, 2025Final
Citation 1, item 5
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$1,400$1,400Mar 20, 2025Final
Citation 1, item 6
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$1,400$1,400Mar 20, 2025Final
Citation 1, item 7
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$1,400$1,400Mar 20, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(10)

(10) Scaffold components manufactured by different manufacturers shall not be intermixed unless the components fit together without force and the scaffold's structural integrity is maintained by the user. Scaffold components manufactured by different manufacturers shall not be modified in order to intermix them unless a competent person determines the resulting scaffold is structurally sound.

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.451(c)(1)

(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:

29 CFR 1926.452 · Rules for each type of scaffold

Other other foundation, structure, and building exterior contractors employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.