OSHA SearchOSHA records by employer

J. M. Beiler Enterprise, LLC: OSHA inspections and violations

Lebanon, Pennsylvania · Structural Steel and Precast Concrete Contractors · NAICS 238120

3inspections
4citation items
$12,164current penalties
Jun 4, 2020last inspection

OSHA has inspected J. M. Beiler Enterprise, LLC 3 times in Pennsylvania since 2014.

The latest one began on Jun 4, 2020 after a complaint, in Oley.

Those inspections ended with 4 citation items: 2 serious and 2 other-than-serious.

Penalties were first proposed at $16,155 and now stand at $12,164, 25% lower after settlements or reviews.

Fall protection comes up most often in these citations: 2 items under 1926.760.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and J. M. Beiler Enterprise, LLC averages $8,500 (1 cited inspection).

J. M. Beiler Enterprise, LLC: OSHA citation items per year, 2014 to 2020
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

277employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch J. M. Beiler Enterprise, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344777610 OPENED JUN 4, 2020Closed

Complaint · Partial · Safety · 11 employees at the site · Closed Jun 21, 2021

450 Main St, Oley, PA 19547 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$11,875$8,500Aug 27, 2020Final

Inspection 339677627 OPENED APR 16, 2014Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jun 19, 2014

Regupol America, Llc 33 Keystone Drive, Lebanon, PA 17042 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.602(c)(1)(vi) · Earthmovers and forklifts in construction
Other-than-serious$1,760$1,144May 19, 2014Final
Citation 2, item 1
29 CFR 1926.760(c)(3) · Fall protection
Other-than-serious$0$0May 19, 2014Final

Inspection 339644320 OPENED MAR 19, 2014Closed

Unprogrammed other · Complete · Safety · 8 employees at the site · Closed Jun 19, 2014

33 Keystone Drive, Lebanon, PA 17042 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.760(c)(3) · Fall protection
Serious$2,520$2,520May 22, 2014Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.602 · Earthmovers and forklifts in construction

29 CFR 1926.602(c)(1)(vi)

(c) Lifting and hauling equipment (other than equipment covered under subpart N of this part). (1) Industrial trucks shall meet the requirements of § 1926.600 and the following:

29 CFR 1926.760 · Fall protection

29 CFR 1926.760(c)(3)

(3) The boundaries of a CDZ shall be designated and clearly marked. The CDZ shall not be more than 90 feet (27.4 m) wide and 90 (27.4 m) feet deep from any leading edge. The CDZ shall be marked by the use of control lines or the equivalent. Examples of acceptable procedures for demarcating CDZ's can be found in appendix D to this subpart.

Other structural steel and precast concrete contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.