J M Electrical Services: OSHA inspections and violations

Rock Springs, Wyoming · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
4citation items
$7,245current penalties
Oct 15, 2021last inspection

OSHA inspectors have visited J M Electrical Services in Wyoming one time.

It opened on Oct 15, 2021 as a planned inspection, in Rock Springs.

In all, OSHA issued 4 citation items: 3 serious and 1 other-than-serious.

The penalties, $7,245 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. J M Electrical Services averages $7,245 across 1 cited inspection.

J M Electrical Services: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Wyoming · latest 90 days of OSHA records

31employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Wyoming: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wyoming

Checking a subcontractor, a client or your own company? Watch J M Electrical Services and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345584445 OPENED OCT 15, 2021Closed

Planned · Partial · Safety · 4 employees at the site · Closed Feb 7, 2022

2400 Cascade Dr., Rock Springs, WY 82901 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,415$2,415Dec 27, 2021Final
Citation 1, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$2,415$2,415Dec 27, 2021Final
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,415$2,415Dec 27, 2021Final
Citation 2, item 1
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Dec 27, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)(i)

(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

29 CFR 1926.503 · Fall protection training in construction