OSHA SearchOSHA records by employer

J. S. Haren Company: OSHA inspections and violations

Conyers, Georgia · Other Foundation, Structure, and Building Exterior Contractors · NAICS 238190

3inspections
2citation items
$2,380current penalties
Jul 22, 2015last inspection

OSHA has inspected J. S. Haren Company 3 times in Georgia since 1995.

The latest one began on Jul 22, 2015 as a planned inspection, in Reidsville.

Those inspections ended with 2 citation items: 1 serious and 1 other-than-serious.

Penalties were first proposed at $2,380 and still stand at $2,380.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and J. S. Haren Company averages $2,380 (1 cited inspection).

J. S. Haren Company: OSHA citation items per year, 1995 to 2015
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

156employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch J. S. Haren Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340799352 OPENED JUL 22, 2015Closed

Planned · Complete · Safety · 40 employees at the site · Closed Jan 26, 2016

1978 Ga Highway 147, Reidsville, GA 30453 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$2,380$2,380Dec 17, 2015Final
Citation 2, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Other-than-serious$0$0Dec 17, 2015Final

Inspection 340149327 OPENED DEC 15, 2014Closed

Planned · No inspection · Safety · 9 employees at the site · Closed Dec 29, 2014

601 Palmetto Street, Saint Simons Island, GA 31522 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 109298091 OPENED SEP 14, 1995Closed

Complaint · Partial · Safety · 27 employees at the site · Closed Sep 14, 1995

Highway 138, Conyers, GA 30200 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.701(b)

(b) Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, shall be guarded to eliminate the hazard of impalement.

Other other foundation, structure, and building exterior contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.