OSHA SearchOSHA records by employer

J S M Masonry, LLC: OSHA inspections and violations

Jacksonville, Florida · Masonry Contractors · NAICS 238140

1inspections
5citation items
$3,800current penalties
Mar 2, 2016last inspection

J S M Masonry, LLC has one OSHA inspection on record in Florida.

OSHA opened it on Mar 2, 2016 as a planned inspection, in Jacksonville.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $7,600 in penalties. After settlements and reviews the total is $3,800, down 50%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. J S M Masonry, LLC averages $3,800 over 1 cited inspection in that time.

J S M Masonry, LLC: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

321employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch J S M Masonry, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341293660 OPENED MAR 2, 2016Closed

Planned · Complete · Safety · 5 employees at the site · Closed Jun 16, 2016

1234 Beach Blvd., Jacksonville, FL 32099 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$2,800$1,400May 6, 2016Final
Citation 1, item 2a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,000$1,000May 6, 2016Final
Citation 1, item 3b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0May 6, 2016Final
Citation 1, item 4c
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0May 6, 2016Final
Citation 1, item 5
29 CFR 1926.502(b)(2) · Fall protection systems
Serious$2,800$1,400May 6, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(1)

(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.502 · Fall protection systems

Other masonry contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.