OSHA SearchOSHA records by employer

J3 Construction, Inc. dba O'Hara's Son Roofing Company: OSHA inspections and violations

Chicago, Illinois · Roofing Contractors · NAICS 238160

2inspections
4citation items
$10,606current penalties
Jan 5, 2021last inspection

OSHA has inspected J3 Construction, Inc. dba O'Hara's Son Roofing Company 2 times in Illinois since 2018.

The latest one began on Jan 5, 2021 after a complaint, in Chicago.

Those inspections ended with 4 citation items: 3 serious and 1 other-than-serious.

Penalties were first proposed at $14,160 and now stand at $10,606, 25% lower after settlements or reviews.

Electrical safety in construction comes up most often in these citations: 2 items under 1926.416.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and J3 Construction, Inc. dba O'Hara's Son Roofing Company averages $5,303 (2 cited inspections).

J3 Construction, Inc. dba O'Hara's Son Roofing Company: OSHA citation items per year, 2018 to 2021
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

417employers cited

157 of them in the same industry

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch J3 Construction, Inc. dba O'Hara's Son Roofing Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345086664 OPENED JAN 5, 2021Closed

Complaint · Partial · Safety · 30 employees at the site · Closed Jul 13, 2021

1744 N. Western Ave., Chicago, IL 60647 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(1) · Tools—Hand and Power: general requirements
Serious$5,106$5,106Apr 8, 2021Final
Citation 2, item 1
29 CFR 1926.502(d)(15) · Fall protection systems
Other-than-serious$0$0Apr 8, 2021Final

Inspection 343542817 OPENED OCT 10, 2018Closed

Unprogrammed related · Partial · Safety · 8 employees at the site · Closed Aug 8, 2019

676 N. Kingsbury St., Chicago, IL 60654 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Incident on May 22, 2018: Two employees are shocked/burned by overhead power line

At 11:00 a.m. on May 22, 2018, Employees #1 and #2, employed by a roofing company, were working at a multiemployer construction project, a seven-story multifamily residential building. They were working from the basket of an aerial lift and installing aluminum trim to the building's exterior. The basket was positioned between the building and energized overhead primary power lines 39 feet above the ground. As Employee #1 handled a 10-foot piece of aluminum trim, the metal came into contact with a power line, and Employee #1 was shocked. Employee #2 turned and observed Employee #1 being shocked. Employee #2 hit the aluminum trim with a tube of caulk to free Employee #1 from the electric current. In so doing, Employee #2 also was shocked. Emergency services were called, and the two employees were transported to the hospital. They were treated for electric shock and burns. One employee required hospitalization, and the other was released after treatment. NOTE: I WAS NOT ABLE TO DETERMINE WHICH EMPLOYEE WAS HOSPITALIZED.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$9,054$5,500Nov 6, 2018Final
Citation 1, item 1b
29 CFR 1926.416(a)(3) · Electrical safety in construction
Serious$0$0Nov 6, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(1)

(b) Guarding. (1) When power operated tools are designed to accommodate guards, they shall be equipped with such guards when in use.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.416(a)(3)

(3) Before work is begun the employer shall ascertain by inquiry or direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, is so located that the performance of the work may bring any person, tool, or machine into physical or electrical contact with the electric power circuit. The employer shall post and maintain proper warning signs where such a circuit exists. The employer shall advise employees of the location of such lines, the hazards involved, and the protective measures to be taken.

29 CFR 1926.502 · Fall protection systems

Other roofing contractors employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.