Jackson - Public Works Administration Building: OSHA inspections and violations

Jackson, Tennessee · Executive Offices · NAICS 921110

1inspections
3citation items
$0current penalties
Sep 12, 2022last inspection

OSHA inspectors have visited Jackson - Public Works Administration Building in Tennessee one time.

It opened on Sep 12, 2022 as a planned inspection, in Jackson.

In all, OSHA issued 3 citation items: 3 serious.

No penalty came with these citations.

The rule cited most here is 1910.305 (electrical wiring methods), 2 times.

Among public administration employers, the typical cited inspection since 2015 ends with a $0 penalty. Jackson - Public Works Administration Building averages $0 across 1 cited inspection.

Jackson - Public Works Administration Building: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

323employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Jackson - Public Works Administration Building and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346217391 OPENED SEP 12, 2022Closed

Planned · Complete · Safety · Local government · 81 employees at the site · Closed Oct 28, 2022

180 S. Conalco Street, Jackson, TN 38301 · Executive Offices · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Sep 28, 2022Final
Citation 1, item 2
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0Sep 28, 2022Final
Citation 1, item 3
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$0$0Sep 28, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(f)(2)

(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(1)(ii)

(ii) Unused openings in cabinets, boxes, and fittings shall be effectively closed.

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.