OSHA SearchOSHA records by employer

Jadl Masonry: OSHA inspections and violations

San Antonio, Texas · Masonry Contractors · NAICS 238140

1inspections
7citation items
$19,400current penalties
Mar 22, 2018last inspection

Jadl Masonry has one OSHA inspection on record in Texas.

OSHA opened it on Mar 22, 2018 as a planned inspection, in San Antonio.

From that inspection OSHA issued 7 citation items: 7 serious.

OSHA proposed $19,400 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (6 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Jadl Masonry averages $19,400 over 1 cited inspection in that time.

Jadl Masonry: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Jadl Masonry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343037438 OPENED MAR 22, 2018Closed

Planned · Partial · Safety · 2 employees at the site · Closed Oct 17, 2022

411 E. Quincy St., San Antonio, TX 78207 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$3,880$3,880Jul 27, 2018Final
Citation 1, item 1b
29 CFR 1926.451(b)(3) · Scaffolds, general requirements
Serious$0$0Jul 27, 2018Final
Citation 1, item 1c
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$0$0Jul 27, 2018Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,880$3,880Jul 27, 2018Final
Citation 1, item 3
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$3,880$3,880Jul 27, 2018Final
Citation 1, item 4
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$3,880$3,880Jul 27, 2018Final
Citation 1, item 5
29 CFR 1926.454(a) · Scaffold training
Serious$3,880$3,880Jul 27, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(b)(3)

(3) Except as provided in paragraphs (b)(3) (i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling.

29 CFR 1926.451(b)(5)(ii)

(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.