OSHA SearchOSHA records by employer

Jaime Mireless: OSHA inspections and violations

Marion, North Carolina · Masonry Contractors · NAICS 238140

1inspections
4citation items
$4,200current penalties
Jul 30, 2020last inspection

OSHA inspectors have visited Jaime Mireless in North Carolina one time.

It opened on Jul 30, 2020 on a referral, in Marion.

In all, OSHA issued 4 citation items: 4 serious.

The penalties, $4,200 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Jaime Mireless averages $4,200 across 1 cited inspection.

Jaime Mireless: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Want to know if OSHA cites Jaime Mireless again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344863386 OPENED JUL 30, 2020Closed

Referral · Partial · Safety · 4 employees at the site · Closed Aug 27, 2024

709 West Henderson St., Marion, NC 28752 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$2,100$2,100Sep 15, 2020Final
Citation 1, item 2a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,100$2,100Sep 15, 2020Final
Citation 1, item 2b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Sep 15, 2020Final
Citation 1, item 2c
29 CFR 1926.452(c)(3) · Rules for each type of scaffold
Serious$0$0Sep 15, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.452 · Rules for each type of scaffold

Other masonry contractors employers in North Carolina

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.