OSHA SearchOSHA records by employer

Jam Roofing Inc.: OSHA inspections and violations

Greenwood Village, Colorado · Roofing Contractors · NAICS 238160

4inspections
4citation items
$8,450current penalties
Jan 4, 2019last inspection

Since 2009, OSHA inspectors have visited Jam Roofing Inc. in Colorado 4 times.

The most recent inspection opened on Jan 4, 2019 after a complaint, in Briggsdale.

In all, OSHA issued 4 citation items: 3 serious and 1 repeat.

The proposed penalties came to $12,075; today they stand at $8,450, 30% less.

The rule cited most here is 1926.501 (fall protection in construction), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Jam Roofing Inc. averages $1,700 across 1 cited inspection.

Jam Roofing Inc.: OSHA citation items per year, 2009 to 2019
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

132employers cited

20 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Jam Roofing Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343695094 OPENED JAN 4, 2019Closed

Complaint · Partial · Safety · 3 employees at the site · Closed Aug 27, 2019

415 Leslie St., Briggsdale, CO 80611 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$2,415$1,700Mar 7, 2019Final

Inspection 334964608 OPENED JUN 28, 2012Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Jun 19, 2013

12477 W. Cedar Ave., Lakewood, CO 80228 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Repeat$6,160$4,000Jul 13, 2012Final

Inspection 313419400 OPENED MAY 27, 2010Closed

Planned · Partial · Safety · 5 employees at the site · Closed Oct 5, 2010

2002 W 76th Ave, Denver, CO 80221 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,000$2,000Sep 1, 2010Closed

Inspection 313716474 OPENED DEC 21, 2009Closed

Planned · Complete · Safety · 6 employees at the site · Closed Mar 1, 2010

9211 E. Arapahoe Road, Greenwood Village, CO 80111 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,500$750Jan 29, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

Other roofing contractors employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.