OSHA SearchOSHA records by employer

James Iron Work Inc.: OSHA inspections and violations

Brooklyn, New York · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

2inspections
3citation items
$10,230current penalties
Dec 11, 2019last inspection

James Iron Work Inc. has 2 OSHA inspections on record in New York, the first in 2019.

OSHA's last visit started on Dec 11, 2019 to follow up on an earlier case, in Brooklyn.

Across those inspections OSHA issued 3 citation items: 3 serious.

OSHA proposed $10,230 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. James Iron Work Inc. averages $10,230 over 1 cited inspection in that time.

James Iron Work Inc.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch James Iron Work Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344502562 OPENED DEC 11, 2019Closed

Follow-up · Partial · Safety · 4 employees at the site · Closed Jan 3, 2020

1133 55th Street, Brooklyn, NY 11219 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343908745 OPENED APR 4, 2019Closed

Unprogrammed other · Partial · Safety · 4 employees at the site · Closed Nov 20, 2020

1133 55th Street, Brooklyn, NY 11219 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,410$3,410Sep 20, 2019Final
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,978$3,978Sep 20, 2019Final
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,842$2,842Sep 20, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

Other new multifamily housing construction (except for-sale builders) employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.