OSHA SearchOSHA records by employer

Jar Design Construction: OSHA inspections and violations

Saipan, Northern Mariana Islands · Poured Concrete Foundation and Structure Contractors · NAICS 238110

1inspections
6citation items
$2,142current penalties
Apr 8, 2015last inspection

OSHA has inspected Jar Design Construction once in Northern Mariana Islands.

The inspection began on Apr 8, 2015 as a planned inspection, in Saipan.

That inspection ended with 6 citation items: 6 serious.

Penalties were first proposed at $3,060 and now stand at $2,142, 30% lower after settlements or reviews.

Ground-fault protection on job sites comes up most often in these citations: 2 items under 1926.404.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Jar Design Construction averages $2,142 (1 cited inspection).

Jar Design Construction: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites Jar Design Construction again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 340522218 OPENED APR 8, 2015Closed

Planned · Complete · Safety · 8 employees at the site · Closed Apr 1, 2016

New 2 Story Apartment And Commercial Building Beach Road And Dotse Place, Village Of I-liyang, Saipan, MP 96950 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$1,020$714May 29, 2015Final
Citation 1, item 1b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0May 29, 2015Final
Citation 1, item 2a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,020$714May 29, 2015Final
Citation 1, item 2b
29 CFR 1926.502(b)(2) · Fall protection systems
Serious$0$0May 29, 2015Final
Citation 1, item 3a
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Serious$1,020$714May 29, 2015Final
Citation 1, item 3b
29 CFR 1926.1052(c)(12) · Stairways in construction
Serious$0$0May 29, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(ii)

(ii) One stairrail system along each unprotected side or edge.

29 CFR 1926.1052(c)(12)

(12) Unprotected sides and edges of stairway landings shall be provided with guardrail systems. Guardrail system criteria are contained in subpart M of this part.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

Other poured concrete foundation and structure contractors employers in Northern Mariana Islands

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.